MODEL GBR100
(100 CFM)
4” Duct (Standard):
100 CFM/1.4 Sones @ 0.1 SP, 12.6 Watts
77 CFM/1.5 Sones @ 0.25 SP, 11.6 Watts
50ft
40ft
30ft
20ft
10ft
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.25
0.10
Air Pressure (IN H
2
O)
0
0 30.0 60.0 90.0 120.0 150.0
Air Flow (CFM)
Fan Curve
BreezGreenBuilder GBR100
4” Duct (Standard)
Static Pressure (inches w.g.) 0.1 0.25
Air Flow (CFM) 100 77
Sones 1.4 1.5
Power Consumption (Watts) 12.6 11.6
Energy Eciency (CFM/Watt) 7.9 6.6
Current (Amps) 0.22 Max
Power Rating (V/Hz) 120 / 60
Description
Low noise ceiling/wall mount ventilating fan. Fan is ENERGY
STAR® qualied, HVI, UL, and cUL certied, and can be used
to comply with ASHRAE 62.2 Intermittent Local Exhaust,
CA Title 24 requirements.
DC Motor/Blower
Power rating of 120 volts/60Hz
DC Brushless motor engineered to run continuously
Motor equipped with thermal cuto fuse
Removable with permanently lubricated plug-in motor
Built-in soft start function to increase bearings’ life
Automatically powers OFF when impeller is locked abnormally
Permanently lubricated motor
Self-compensating motor speed for intended airow when
static pressure is encountered
Housing
Galvanized steel body
Detachable 4” diameter duct adapter
Built-in back-draft damper
Hanger bars included
Easy installation
Grille
Attractive design using ABS material
Attaches directly to housing with torsion springs
LED Indicator
Turn the power switch on/o to operate on/o.
LED indicator will be green when power is on
Warranty
3-year limited warranty
TYPICAL SPECIFICATION
Ventilation fan shall be Delta Breez model GBR100; ENERGY
STAR qualied with brushless DC motor engineered to run
continuously for a minimum 70,000 hours; airow rating of
100 CFM and loudness rating of 1.4 Sones at 0.1 static pressure
as certied by the Home Ventilating Institute (HVI); power
consumption of 12.6 Watts with eciency rating of 7.9 CFM/Watt
at 0.1” static pressure; fan will feature LED indicator running light,
motor lock protection and self-compensating motor speed
for intended airow when static pressure is encountered.
UL and cUL listed for tub/shower enclosure when used with
GFCI-protected branch circuit wiring.