Submittal Sheet
46101 Fremont Blvd., Fremont, CA 94538 | tel 1.888.979.9889 | www.deltabreez.com
Model
Quantity
Comments
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
MODEL GBR100H
50ft
40ft
30ft
20ft
10ft
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.25
0.10
Air Pressure (IN H
2
O)
0
0 30.0 60.0 90.0 120.0 150.0
Air Flow (CFM)
Fan Curve
Description
Low noise ceiling/wall mount ventilating fan with humidity
sensor. Fan is ENERGY STAR® qualied , HVI, UL, and cUL certied,
and can be used to comply with ASHRAE 62.2 Intermittent
Local Exhaust, CA Title 24, and CALGreen requirements.
DC Motor/Blower
• Power rating of 120 volts/60Hz
• DC Brushless motor engineered to run continuously
• Motor equipped with thermal cuto fuse
• Removable with permanently lubricated plug-in motor
• Allows fan to operate in full speed mode or humidity
control mode by manual switch
• For humidity control mode, when humidity is above the
user-adjustable set-point, fan runs at full speed (100 CFM).
When humidity is below the set-point, the fan runs
continuously at a pre-set lower level (0 or 60 CFM)
• Built-in soft start function to increase bearings’ life
• Automatically powers OFF when impeller is locked abnormally
• Permanently lubricated motor
• Self-compensating motor speed for intended airow when
static pressure is encountered
Housing
• Galvanized steel body
• Detachable 4” diameter duct adapter
• Built-in backdraft damper
• Hanger bars included
• Easy installation
Grille
• Attractive design using ABS material
• Attaches directly to housing with torsion springs
LED Indicator
• Blue and amber LED indicator lights to show humidity
sensor and full speed modes
Warranty
• 3-year limited warranty
TYPICAL SPECIFICATION
Ventilation fan shall be Delta Breez model GBR100H; ENERGY
STAR® qualied with DC brushless motor engineered to run
continuously for a minimum 70,000 hours; airow rating of
100 CFM and loudness rating of 1.4 Sones at 0.1 static
pressure as certied by the Home Ventilating Institute (HVI);
power consumption of 12.6 Watts with eciency rating of
7.9 CFM/Watt at 0.1” static pressure; fan will feature LED indicator
running light, motor lock protection and self-compensating
motor speed for intended airow when static pressure is
encountered. UL and cUL listed for tub/shower enclosure
when used with GFCI-protected branch circuit wiring.
10 ¾"
10 ¾"
Full Speed
100CFM
Low Speed
60CFM
GreenBuilder GBR100H Continuous low speed
Full speed
Static Pressure (inches w.g.) 0.1 0.25 0.1 0.25
Energy Eciency (CFM/Watt) 12.2 6.6 7.9 6.1
Current (Amps) 0.24 Max
Power Rating (V/Hz) 120 / 60
Sones 0.5 0.7 1.4 1.5
Power Consumption (Watts) 4.9 6.3 12.6 12.5
Air Flow (CFM) 60 42 100 77
%RH
50
60
0
60
70
80
LOW SPEED
CFM
Control Options
Full Speed:
100 CFM/1.4 Sones @ 0.1” SP, 12.6 Watts
77 CFM/1.5 Sones @ 0.25” SP, 12.5 Watts
Low Speed:
60 CFM/0.5 Sones @ 0.1” SP, 4.9 Watts
46 CFM/0.7 Sones @ 0.25” SP, 6.3 Watts
8”
8 ¾”
4”
5 ¾”
(Fan with Humidity Sensor - 100 CFM)