Technical Specifications

46101 Fremont Blvd., Fremont, CA 94538 | tel 1.888.979.9889 | www.deltabreez.com
Model
Quantity
Comments
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
MODEL SLM80
(80 CFM)
Description
Low noise ceiling or wall mount ventilating fan, rated for
continuous running. ENERGY STAR® qualied. HVI, UL and cUL
certied to comply with ASHRAE 62.2 local and whole
building continuous and intermittent operation. Meets CA
Title 24 and CALGreen requirements.
DC Motor/Blower
Power rating of 120 volts/60Hz
Motor equipped with thermal cuto fuse
Removable with permanently lubricated plug-in motor
Built-in soft start function to increase bearings’ life
Automatically powers OFF when impeller is locked
abnormally
Housing
Galvanized steel body
Detachable 4” oval metal duct adapter
Built-in backdraft damper
Includes 4” oval duct to 3” round duct reducer
Easy installation
Grille
Attractive design using ABS material
Attaches directly to housing with torsion springs
LED Indicator
Turn the power switch on/o to operate on/o.
LED indicator will be green when power is on
Warranty
3-Year limited warranty
TYPICAL SPECIFICATION
Ventilation fan shall be Delta Breez model SLM80; ENERGY
STAR qualied with Brushless DC Motor engineered to run
continuously for a minimum 70,000 hours; airow rating of
80 CFM and loudness rating of 0.6 Sones at 0.1 static
pressure as certied by the Home Ventilating Institute (HVI); power
consumption of 8.5 Watts with eciency rating of 9.4 CFM/Watt;
fan will feature LED indicator running light and motor lock
protection. UL and cUL listed for tub/shower enclosure
when used with GFCI-protected branch circuit wiring
4” Oval Duct:
80 CFM/0.6 Sones @ 0.1 SP, 8.5 Watts
66 CFM/1.1 Sones @ 0.25 SP, 10.9 Watts
3” Round Duct:
70 CFM/0.9 Sones @ 0.1 SP, 10.5 Watts
57 CFM/1.5 Sones @ 0.25 SP, 12.0 Watts
0.1 0.25 0.1 0.25
80 62 70 54
0.6 1.1 0.9 1.5
8.5 10.9 10.5 12.0
9.4 5.6 6.6 4.5
SLM80
Static Pressure (inches w.g.)
Air Flow (CFM)
Sones
Power Consumption (Watts)
Energy Eciency (CFM/Watt)
Current (Amps)
Power Rating (V/Hz)
4” oval duct 3” round duct
0.26 Max
120/60
Fan Curve SLM80
4” Oval Duct 3” Round Duct
0.60
0.70
0.50
0.40
0.30
0.20
0
0.25
0.10
0 30.0 60.0 90.0 120.0
Air Pressure (IN H
2
O)
Air Flow (CFM)
100ft 80ft 60ft 40ft
20ft
100ft 80ft
60ft
40ft
20ft
0.60
0.70
0.50
0.40
0.30
0.20
0
0.25
0.10
0 30.0 60.0 90.0 120.0
Air Pressure (IN H
2
O)
Air Flow (CFM)
14”
14”
3”
4” Oval duct
11 ¼”
10 ½”
4”
3” Round duct

Summary of content (1 pages)