Specification
Delta BreezSmart Ventilation
Humidity Sensor Fan
SMT130H 05/13
(IN H O)
Air Flow
0
2
0 30.0 60.0 90.0 120.0 150.0
(CFM)
Air Pressure
20ft
0.6
0.7
0.8
0.9
0.5
0.4
0.1
0.3
0.2
0.25
40ft
60ft
80ft
100ft
50CFM
70CFM
90CFM
130CFM
Fan Curve
Description
Motor/Blower
• Power rating of 120volts/60Hz
• DC brushless motor engineered to run continuously
•
• Removable with permanently lubricated motor
Housing
• Galvanized steel body
• Detachable 6” diameter metal duct adapter
• Built-in backdraft damper
• Easy installation with expandable extension bracket
Grille
• Attractive design using ABS material
• Attaches directly to housing with torsion springs
Warranty
• 3-year limited warranty
Features
• Blue and amber LED indicator lights to show humidity control and full speed modes
• Adjustable humidity set points between ~50% to ~90% RH
•
•
•
CFM/Watt at 0.1” static pressure
• UL and cUL listed for tub/shower enclosure when used with GFCI-protected branch circuit
wiring
DC Motor Technology
• Allows fan to operate in full speed mode or humidity control mode by manual switch
• For humidity control mode, when humidity is above the user-adjustable set-point, fan runs at
full speed (130 CFM). When humidity is below the set-point, the fan runs continuously at a
user-preset lower level (0, 50, 70, 90 CFM)
• Built-in soft start function to increase bearings’ life
•
SMT130H
(130 CFM)
SMT130H
Fan Speed
Static Pressure (Inches w.g.)
Air Flow (CFM)
Sones
Power Consumption (Watts)
Current (Amps)
Power Rating (V/Hz)
6” Duct (Standard)
Continuous Low Speed Full Speed
0.44 Max
120/60
0.1
70
<0.3
6.9
10.1
0.25
68
0.7
12.0
5.6
0.1
50
<0.3
5.6
8.9
0.25
49
0.7
10.7
4.5
0.1
90
<0.3
8.0
11.2
0.25
88
0.7
14.0
6.2
0.25
124
0.7
20.0
6.2
0.1
130
<0.3
11.6
11.2
Dimensions
4405 Cushing Parkway | Fremont, CA 94538
tel 1.888.979.9889 | www.deltabreez.com
Built-in Controls
6"
11.375"
10.5"
7.625"
14"
14"
Low noise ceiling mount ventilating fan rated for continuous running. Fan has been awarded
ENERGY STAR® Most Ecient in 2013, HVI certied, ASHRAE 62.2 (continuous and intermittent
operation), CALGreen, and CA Title 24 compliant, and is evaluated by Underwriter Laboratories,
conforming to both UL and cUL safety standards.