Installation and User Guide MINOR 11 DELTA DORE - Bonnemain 35270 COMBOURG - FRANCE E-mail : deltadore@deltadore.com Device compliant with the requirements of directives: 2004/108/CEE (Electromagnetic compatibility) and 2006/95/CEE (Low voltage safety) Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this document are not binding unless confirmed by Delta Dore. *2702007_rev.
Warnings 1- Contents • Carefully read these instructions prior to installation. • The unit must be installed in compliance with currently applicable standards. • Always switch off the mains before installing or servicing the unit. • Do not attempt to repair the unit yourself; an after-sales service is available. • The diagrams provided are simplified for greater clarity. The protective units and other accessories required by the standards are not illustrated.
2- Presentation Relay status Current mode Set-point temperature or temperature measured per MINOR 11 Heating demand mode Auto Off Comfort Selection of the operating mode or configuration (installer) Economy Frost Protection Adjustment buttons 15 mm 33 mm • Suitable for underfloor heating or radiant ceiling heating • Permanent regulation (proportional integral) • Simple control system (pilot wire principle) • Up to 6 operating modes (GIFAM standard) 2.
3- Location 4- Mounting / Connection The MINOR 11 thermostat is mounted flush-mounted in a flush-mounted box. It should be placed in a room whose temperature represents the mean temperature, with a recommended height of 1.5 m and it should be away from any heat sources (fireworks, sunlight) and from air flows (window, door, etc.). To avoid unwanted air movements that would distort the sensor measurement, the wire entry into the flush-mounted box must be plugged (mastic, glass wool, etc.). Approx.
- Connections L 6- Switching on the unit for the first time MINOR 11 Load L 10A - 230V Pilot Underfloor N Wire sensor 6 7 Pilot wire from programmer Maximum load 2.300 W Max. power: 2,300 W, otherwise relay L MINOR 11 Load L 10A - 230V N Pilot Underfloor Wire sensor 6 7 Pilot wire from programmer load The relay capacity depends on the power to be switched The reference number of the underfloor sensor to use is 6300037.
7- Installer commissioning To enter this mode, press the button for 10 seconds until CF01 is displayed. 7.1 Choosing the temperature displayed (CF01) : Temperature of the room measured by MINOR 11 : Current set-point temperature (default mode) Select by pressing the or buttons and , confirm by pressing and releasing . Go on to the next menu. 7.2 Choosing the control sensor (CF02) : Sensor within the casing (by default) 7.
.4 Locking user access (CF06) 7.5 Choosing the installation type (CF07) Important: Before activating the user locking feature, select the required operating mode ( ). This menu is used to determine the type of installation so that the most suitable regulation settings are used. : Les touches sont verrouillées. Only the set-point configured before the locking operation can be changed to +/- 3°C (except for the and modes). : Active buttons (default display).
7.7 Power to be switched (CF10) This parameter is only displayed if the Underfloor heating mode (CF07 - § 7.5) and the internal sensor (CF02 - § 7.2) are selected. : Up to 1,000 W (direct control) : From 1,000 W to 2,300 W (direct control, by default) : Greater than 2,300 W (contact switch control) Press the button several times for rapid access to a specific menu 8- Operation 8.
When a choice is made to display the current temperature (default mode, § 7.1), the first time the button or is pressed will display room temperature, pressing it a second time allows you to adjust the set-point. 8.2.2 Underfloor sensor set-point setting (selection of sensor type made in § 7.2) Select the mode to set ( by the button . or , Frost protection) Use or , to make your choice (setting of 5 to 40°C for Comfort or Economy, and 5 to 30°C for Frost protection).
Mechanical • Dimensions: LxHxD = 80 x 80 x 48 mm • IP 30 • Wall-mounted on flush-mounted box • Installation in an environment with normal pollution levels Technical • Storage temperature: -10°C to +70°C • Operating temperature: 0°C to +40°C.