User's Manual

DS_NE12S06A_06302008
10
THERMAL CURVES (VERTICAL)
NE12S0A0V06(standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin=12V Vout=5.0V (Either Orientation)
0
1
2
3
4
5
6
25 30 35 40 45 50 55 60 65 70 75 80 85
Natural
Convection
300LFM
Output Current (A)
Ambient Temp erature ()
400LFM
600LFM
100LFM
200LFM
500LFM
Figure 29: Output current vs. ambient temperature and air
velocity @Vin=12V, Vout=5.0V (Either Orientation)
NE12S0A0V06(standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin=5.0V Vout=0.9V (Either Orientation)
0
1
2
3
4
5
6
25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Te mperature (
)
Output Current (A)
Natural
Convection
Figure 30: Output current vs. ambient temperature and air
velocity@ Vin =5V, Vout=0.9V (Either Orientation)
NE12S0A0V06(standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin=5.0V Vout=2.5V (Either Orientation)
0
1
2
3
4
5
6
25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Te mperature ()
Output Current (A)
Natural
Convection
Figure 31: Output current vs. ambient temperature and air
velocity@ Vin =5V, Vout=2.5V (Either Orientation)
NE12S0A0V06(standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin=3.3V Vout=0.9V (Either Orientation)
0
1
2
3
4
5
6
25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Te mperature (
)
Output Current (A)
Natural
Convection
Figure 32: Output current vs. ambient temperature and air
velocity @Vin=3.3V, Vout=0.9V (Either Orientation)
NE12S0A0V06(standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin=3.3V Vout=2.5V (Either Orientation)
0
1
2
3
4
5
6
25 30 35 40 45 50 55 60 65 70 75 80 85
Ambient Te mperature ()
Output Current (A)
Natural
Convection
Figure 33: Output current vs. ambient temperature and air
velocity@ Vin =3.3V, Vout=2.5V (Either Orientation)