Specifications

8
VFD-G Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
8-17
Parameters Functions Settings
Factory
Setting
Customer
a
09-06 Communication Operation
Command 1
Bit8~11:
0000: Master speed
0001: 1
st
step speed
0010: 2
nd
step speed
0011: 3rd step speed
0100: 4th step speed
0101: 5th step speed
0110: 6th step speed
0111: 7th step speed
1000: 8th step speed
1001: 9th step speed
1010: 10th step speed
1011: 11th step speed
1100: 12th step speed
1101: 13th step speed
1110: 14th step speed
1111: 15th step speed
Bit12: Select Bit6~11 function
Bit13~15 Reserved
00
a
09-07 Communication
Frequency Setting
0~160.00Hz 60.00
a
09-08 Communication Operation
Command 2
Bit0: 1: EF ON
Bit1: 1: Reset
Bit2: 0: BB OFF, 1: BB ON
Bit3~15: Reserved
00