Chapter 5 Description of Parameter Settings
© 1999 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
22
CH 5-1 Group 0: User Parameters
0 - 00 Identity Code of AC Motor Drive Factory setting: d #
Settings None
V \ HP 1/4 1/2 1 2 3
115V/230V d 0 d 2 d 4 d 6 d 8
460V -- -- -- d 3 d 5 d 7 d 9
& This parameter shows the capacity of the AC drive. Users can read Pr.0-01 to
check if it is the rated current of the AC drive corresponds to the identity code
shown above and the current shown below.
V \ HP 1/4 1/2 1 2 3
115V/230V 1.6A 2.5A 4.2A 7.5A 11.0A
460V -- -- -- 1.5 A 2.5 A 4.2 A 5.5 A
0 - 01 Rated Current Display of the AC drive Factory Setting: d ##.#
Settings None Unit: 0.1A
& This parameter displays the rated current of the AC drive. It will display based
on Pr.0-00, and is read-only.
0 - 02 Parameter Reset Factory Setting: d 0
Settings d 0 to d 9 Not used
d 10 All parameters are reset to be factory settings
& This setting allows the user to return all parameters to the factory default
settings.