User manual

Chapter 5 Description of Parameter Settings
© 1999 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
55
2nd Accel/
d13, d14 External Base Block:
Parameter values d13, d14 program Multi-Function Input Terminals: M1 (Pr.4-
04), M2 (Pr.4-05), M3 (Pr.4-06), M4 (Pr.4-07) or M5 (Pr.4-08) for external Base
Block control. Value d13 is for normally open (N.O.) input, and value d14 is for
a normally closed (N.C.) input.
Note: When a Base-Block signal is received, the AC drive will stop all output and
the motor will free run. When base block control is deactivated, the AC
drive will start its speed search function and synchronize with the motor
speed, and then accelerate to Master Frequency.