6 - 03 Over-Torque Detection Mode Factory Setting: d 0
Settings d 0 Over-Torque detection disabled.
d 1 Over-Torque detection enabled during constant
speed operation (OL2), and operation continues
until the continuous operation limit (Pr.6-05) is
reached.
d 2 Over-Torque detection enabled during constant
speed operation, and operation halted after over-
torque detection.
d 3 Over-Torque detection enabled during acceleration,
and operation continues before the Continuous
Output Time Limit (Pr.6-05) is reached.
d 4 Over-Torque detection enabled during acceleration,
and operation halted after over-torque detection