Chapter 8 Summary of Parameter Settings
© 1999 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
107
Group 3 Output Function Parameters
Parameters Explanation Settings
Factor
y
Setting
d0: analog frequency
3-00 Analog Output Signal
d1: analog current
0
3-01 Analog Output Gain H 1 to 200% 100
3-02 Desired Freq. Attained 1.0 to 400 Hz 1.0
3-03 Terminal Count Value 0 to 999 0
3-04 Preliminary Count Value 0 to 999 0
3-05
Multi-Function Output1
(Photocoupler Output)
d0: Not Used 1
d1: AC Drive Operational
d2: Max. Output Freq. Attained
d3: Zero Speed
d4: Over Torque
d5: Base-Block (B.B.)
d6: Low Voltage Detection
d7: AC Drive Operation Mode
d8: Fault Indication
d9: Desired Freq. Attained
d10: PLC Program Running
d11: PLC Program Step Complete
d12: PLC Program Complete
d13: PLC Program Operation Pause
d14: Terminal Count Value Attained
d15: Preliminary count Value Attained
3-06
Multi-Function Output2
(Relay Output)
d16: All Functions Normal
8