Chapter 8 Summary of Parameter Settings
© 1999 DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
110
Group 6 Protection Parameters
Parameters Explanation Settings
Factory
Setting
d0: Disable
6-00
Over-Voltage Stall
Prevention
d1: Enable
1
6-01
Over-Current Stall
Prevention during
Accel
20 to 250% 170
6-02
Over-Current Stall
Prevention during
Operation
20 to 250% 170
d0: Disabled
d1: Enabled during constant speed operation
and continues until the continuous limit
(Pr.6-05) is reached.
d2: Enabled during Constant Speed
Operation and halted after detection
d3: Enabled during Accel and continues
before Continuous Output Time Limit
(Pr.6-05) is reached
6-03
Over-Torque
Detection Mode
d4: Enabled during Accel and halted after
Over-Torque detection
0
6-04
Over-Torque
Detection Level
30 to 200% 150
6-05
Continuous Output
Time Limit
0.1 to 10.0 Sec 0.1
6-06
Electronic Thermal
Overload Relay
0 to 2 2
6-07
Electronic Thermal
characteristic H
30 to 600 Sec 60
6-08 Present Fault Record d0: No Fault occurred
6-09 Second Most Recent
Fault Record
d1: Over Current (oc)
d2: Over Voltage (ov)
d3: Over Heat (oH)
d4: Over Load (oL)
d5: Over Load (oL1)
6-10
Third Most Recent
Fault Record
d6: External Fault (EF)
0