TECHNICAL DATASHEET
CliQ DIN Rail
Power
Supply
12V 15W 1
Phase
/ DRP012V015W1A
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (September 2013, Rev. 03)
4
Safety Standards / Directives
Electronic Equipment in Power Installations EN50718 / IEC62103
Electrical Safety
TUV Bauart to EN60950-1, UL/cUL recognized to
UL60950-1, CSA C22.2 No. 60950-1, CB scheme to
IEC60950-1
Industrial Control Equipment UL/cUL listed to UL508 and CSA C22.2 No. 107.1-01,
CSA to CSA C22.2 No. 107.1-01
Hazardous Location / ATEX (For DRP012V015W1AY) cCSAus to CSA C22.2 No.213-M1987, ANSI / ISA
12.12.01:2007 Class I, Division 2, Group A,B,C,D T4
EN60079-0:2009, EN60079-15:2010
( II 3GII 3G Ex nA IIC T4 Gc)
II 3G ATEX 94/9/EC; (For DRP024V060W1BA)
IECEX Test Report
Certificate No. EPS 12 ATEX 1 491 X
For IEC60079-0, IEC60079-15
CE In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
For DRP012V015W1AY:
In conformance with Equipment for explosive
atmospheres (ATEX) directive 94/9/EC
Material and Parts RoHS Directive 2011/65/EU Compliant
Galvanic Isolation Input to Output 4.0KVac
Input to Ground 1.5KVac
Output to Ground 1.5KVac
EMC
EMC / Emissions CISPR22, EN55022, EN55011, FCC Title 47: Class B
Immunity to
Electrostatic Discharge EN61000-4-2 Level 4 Criteria A
1)
Air Discharge: 15kV
Contact Discharge: 8kV
Radiated Field EN61000-4-3 Level 3 Criteria A
1)
80MHz1GHz, 10V/M with 1kHz tone / 80% modulation
Electrical Fast Transient / Burst EN61000-4-4 Level 3 Criteria A
1)
2kV
Surge IEC6100-4-5 Level 3 Criteria A
1)
Common Mode
2)
: 2kV
Differential Mode
3)
: 1kV
Conducted EN61000-4-6 Level 3 Criteria A
1)
150kHz-80MHz, 10Vrms
Power Frequency Magnetic Fields EN61000-4-8 Level 3 Criteria A
1)
10A/Meter
Voltage Dips EN61000-4-11 Level 3 Criteria A
1)
100% dip; 1 cycle (20ms); Self Recoverable
Low Energy Pulse Test (Ring Wave) IEC61000-4-12 Level 3 Criteria A
1)
Common Mode
2)
: 2kV
Differential Mode
3)
: 1kV
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)