Input Characteristics 
Parameter  Model  Min.  Typ.  Max.  Unit 
24V Input Models  -0.7 
--- 
50 
Input Surge Voltage (1 sec. max.) 
48V Input Models  -0.7 
--- 
100 
24V Input Models  7 8 9 
Start-Up Voltage 
48V Input Models  14 16 18 
24V Input Models  --- --- 8.5 
Under Voltage Shutdown 
48V Input Models  --- --- 16 
VDC 
Short Circuit Input Power  --- --- 3000 mW 
Internal Power Dissipation  ---  ---  2500  mW 
Conducted EMI 
All Models 
Compliance to EN 55022,class A and FCC part 15,class A 
Output Characteristics 
Parameter  Conditions  Min.  Typ.  Max.  Unit 
Output Voltage Accuracy    ---  ±1.0  ±2.0  % 
Output Voltage Balance  Dual Output, Balanced Loads ---  ±1.0  ±2.0  % 
Line Regulation  Vin=Min. to Max.  ---  ±0.1  ±0.5  % 
Load Regulation  Io=0% to 100%  ---  ±0.6  ±1.2  % 
Min.Load  No minimum Load Requirement 
Ripple & Noise (20MHz)    ---  50  80  mV
 P-P
Ripple & Noise (20MHz)  Over Line, Load & Temp.  ---  ---  100  mV
 P-P
Transient Recovery Time  ---  300  600  uS 
Transient Response Deviation 
25% Load Step Change 
--- ±3 --- % 
Temperature Coefficient    ---  ±0.01  ±0.02  %/℃ 
Over Load Protection  Foldback  110  150  ---  % 
Short Circuit Protection  Continuous 
General Characteristics 
Parameter  Conditions  Min.  Typ.  Max.  Unit 
Standard 1500  ---  ---  VDC 
I/O Isolation Voltage (rated)  60 Seconds 
Suffix H (note 5) 3000  ---  ---  VDC 
I/O Isolation Resistance  500 VDC  1000  ---  ---  MΩ 
I/O Isolation Capacitance  100KHz, 1V  ---  1000  ---  pF 
Switching Frequency    ---  330  ---  KHz 
MTBF (calculated)  MIL-HDBK-217F@25℃, Ground Benign  800,000  ---  ---  Hours 
Safety Approvals(pending)  UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-scheme) 
Recommended Input Fuse 
24V Input Models  48V Input Models 
1500mA Slow-Blow Type  800mA Slow-Blow Type 
Environmental Characteristics 
Parameter  Conditions  Min.  Max.  Unit 
Operating Temperature Range 
(with Derating) 
Ambient -40 +85 ℃ 
Case Temperature    ---  +100  ℃ 
Storage Temperature Range    -50  +125  ℃ 
Humidity (non condensing)    ---  95  % rel. H 
Cooling  Free-Air convection 
Lead Temperature   
(1.5mm from case for 10Sec.) 
 --- 260 ℃ 
P2 