Technical information

J-40
Above prices do not include VAT. E&OE
Timers & control relays
Control devices
Two hand module Alarm module Multi-start attempt
Flasher
( solid state )
Power supply
2VA 10VA
THC1
GAM3
( 3 circuits )
G10
( 3 starts )
SSF1 PSU/2 PSU/10
THC1twohandcontroldesigned
asasafetydeviceformachines
whereoperatorisforcedto
operatetwopushbuttonswithin
0.5secstooperatemachine.
Alatchfacilityisprovidedfor
usewithafootswitch.
Controlofalarmoutputsfrom3
separateN/Oinputs.Closureof
anyalarmcontactenergisesa
lampoutputwhichflashes.
Onacceptanceofthealarm(via
a common “ALARMACCEPT”
p/button)theflashinglamp
steadies and remains so until
alarm conditionisreset.The
GAM3testfacilitatesacommon
“LAMPTEST”facility.The system
canbeexpandedtomanymore
circuits on request by merely
commoningupmodules,theonly
restriction beingthesizeofthe
powersupply.
Toinitiaterepetitivestartingof
standbygeneratingsets.Apply-
ingsupplyinitiatesthefirst1-30
secstartattempt.Ifthisstartis
successful,supplyshouldbe
removed.Aslongassupply
remainstherelaywillstartagain
afteranequaldwellperiod.If
thegeneratorfailstostartwithin
3attemptsthestartingsequence
willterminateandtheseparate
alarmrelaywillenergise.Can
besuppliedwithupto9starts
Solidstateflasherdesignedto
eliminatemechanicalwear
whenswitchingincandescent
lamps continuously.
Configurableto“STEADY”
after3-5-10secsorflash
continuously.
ProvidesaregulatedDC
outputfromanACinput
source(2VA).
PSU/22VA
PSU/1010VA
AC:12,24,110,230,400V
±15%
DC:12,24,48V±15%
DC:12,24V±10%
(unregulated)
10-30Vdc±10%
AC:110,230,400,525V
±10%
AC:24,110,230±15%
400V(2VA)
110,230,400,525Vareequippedwithinternaltransformer,providingeffectivegalvanicseparationoftheelectroniccircuitryfromsupplyvoltage(testvolts:2kV)
Safetycontrolforapplications
whereguillotinesandpresses
are operated.
Canbesuppliedwithupto
9starts.
LEDindicationof“alarmon”
Twosequenceoutputcontacts
allowsequentialflashing.
Usedtosupplylowcurrent
regulatedDCsupplyfroman
AC source.
Shortcircuitprotectiononthe
output.
10A250Vac 10A250Vac 10A250Vac 5A250Vac
AC:±3VA
DC:±100mA
DC:±600mA DC:±100mA ±3VA
twohandforcedcontrollerfor
safetyoperations
common
“LAMPTEST”(pin7)
“ALARMACCEPT”(pin9)
interruptionofsupplyresets
relay
90pulsesperminute
input:24,110,230,
output:5,9,10,12,24Vdc
389.00 455.00 423.00 443.00 219.00 704.00
Button1
Button2
Latch
4
11
9
8
2
10
5
6
7
Supply
1
3
4
11
9
8
2
10
5
6
7
Alarm
accept
Lamp
test
Alarm3
Alarm2
Alarm1
Lamp 1
Lamp 2
Lamp 3
Hooter
24/12 Vdc
To other
modules
1
3
4
11
9
8
2
10
5
6
7
9-30 Vdc
Supply
Start
Relay
Alarm
Relay
+
-
1
3
4
11
9
8
2
10
5
6
7
Supply
1
3
4
11
9
8
2
10
5
6
7
Supply
Output
+
-