Elevator Drive User Manual

Appendix B Accessories|
Revision Nov. 2008, VLE1, SW V1.03 B-23
2. Wire length
Types of Pulse
Generators
Maximum Wire Length Wire Gauge
Line Driver 100m 1.25mm
2
(AWG16) or above
3. Types of Pulse Generators (Encoders)
Line driver
Q
Q
Z/O
0V
A/O
A/O
B/O
B/O
Z/O
VP
0V
A
A
B
B
Z
Z
PG
EMVL-PGABL
U
U
V
V
W
W
Encoder
4. Output Signal Setting of the Frequency Divider
It generates the output signal of division factor
ā€œnā€ after dealing with the input pulse. Please
set by the switch SW1 on the card.
ON
12 3
4
5678 9101112
RESERVE
I/MODE
O/MODE
RST
Division Factor
BIT0
BIT1
BIT2
BIT3
BIT4
BIT5
BIT6
BIT7
0
1
RESERVE: reserved bit (PIN1)
I/MODE: input type setting of the division
pulse (PIN 2)
O/MODE: output type setting of the division
pulse (PIN 3)
RST: clock reset bit (PIN 4)
Division factor: setting for division factor n:
1~256 (PIN5~12)