Network Device Product Manual
Table Of Contents
- Preface
- Table of Contents
- Chapter 1 Introduction
- Chapter 2 Installation and Wiring
- Chapter 3 Start Up
- Chapter 4 Digital Keypad Operation
- Chapter 5 Parameters
- 5.1 Summary of Parameter Settings
- Group 0 User Parameters
- Group 1 Basic Parameters
- Group 2 Operation Method Parameters
- Group 3 Output Function Parameters
- Group 4 Input Function Parameters
- Group 5 Multi-Step Speed and PLC Parameters
- Group 6 Protection Parameters
- Group 7 Motor Parameters
- Group 8 Special Parameters
- Group 9 Communication Parameters
- Group A PID Parameters
- 5.2 Parameter Settings for Applications
- 5.3 Description of Parameter Settings
- Group 0: User Parameters
- Group 1: Basic Parameters
- Group 2: Operation Method Parameters
- Group 3: Output Function Parameters
- Group 4: Input Function Parameters
- Group 5: Multi-step Speeds and PLC (Process Logic Control) Parameters
- Group 6: Protection Parameters
- Group 7: Motor Parameters
- Group 8: Special Parameters
- Group 9: Communication Parameters
- Group A: PID Control
- 5.1 Summary of Parameter Settings
- Chapter 6 Fault Code Information
- Chapter 7 Troubleshooting
- 7.1 Over Current (OC)
- 7.2 Ground Fault
- 7.3 Over Voltage (OV)
- 7.4 Low Voltage (Lv)
- 7.5 Over Heat (OH)
- 7.6 Overload
- 7.7 Keypad Display is Abnormal
- 7.8 Phase Loss (PHL)
- 7.9 Motor cannot Run
- 7.10 Motor Speed cannot be Changed
- 7.11 Motor Stalls during Acceleration
- 7.12 The Motor does not Run as Expected
- 7.13 Electromagnetic/Induction Noise
- 7.14 Environmental Condition
- 7.15 Affecting Other Machines
- Chapter 8 Maintenance and Inspections
- Appendix A Specifications
- Appendix B Accessories
- Appendix C How to Select the Right AC Motor Drive

Chapter 2 Installation and Wiring|VFD-S Series
Revision August 2008, SE09, SW V2.61 2-21
For VFDXXXSXXE
NPN mode without external power
NOTE
M0
M1
M2
M3
M5
M4
E
GND
+17V
NPN Mode
NPN
J2
PNP
Forward/Stop
Reverse/Stop
Reset
Multi-step 1
Multi-step 2
Multi-step 3
Common Signal
F
a
c
t
o
r
y
S
e
t
t
i
n
g
M
u
l
t
i
-
f
u
n
c
t
i
o
n
I
n
p
u
t
T
e
r
m
i
n
a
l
s
M0
M1
M2
M3
M5
M4
E
GND
+17V
17
V
dc
-
+
NPN mode with external power
Forward/Stop
Reverse/Stop
Reset
Multi-step 1
Multi-step 2
Multi-step 3
M
u
l
t
i
-
f
u
n
c
t
i
o
n
I
n
p
u
t
T
e
r
m
i
n
a
l
s
F
a
c
t
o
r
y
S
e
t
t
i
n
g
Don't apply the mains voltage
directly to above terminals.
NPN
J2
PNP
PNP mode without external power
NOTE
PNP Mode
M0
M1
M2
M3
M5
M4
E
GND
+17V
Forward/Stop
Reverse/Stop
Reset
Multi-step 1
Multi-step 2
Multi-step 3
F
a
c
t
o
r
y
S
e
t
t
i
n
g
M
u
l
t
i
-
f
u
n
c
t
i
o
n
I
n
p
u
t
T
e
r
m
i
n
a
l
s
PNP mode with external power
M0
M1
M2
M3
M5
M4
E
GND
+17V
-
+
17
V
dc
Forward/Stop
Reverse/Stop
Reset
Multi-step 1
Multi-step 1
Multi-step 1
F
a
c
t
o
r
y
S
e
t
t
i
n
g
M
u
l
t
i
-
f
u
n
c
t
i
o
n
I
n
p
u
t
T
e
r
m
i
n
a
l
s
Don't apply the mains voltage
directly to above terminals.










