Users Manual
6
Carbon dioxide
Detecon method
Non-dispersive infrared
(automac calibraon)
Operang range 350-10000 ppm
Precision ± 30ppm ± 3%
Temperature
Detecon method Semiconductors
Operang range 0-50 °C (32-122°F)
Precision ± 1.0 °C (± 1.8 °F)
Humidity
Detecon method Semiconductors
Operang range 0 - 95% rRH
Precision
±5% at 20-80%rH
@ 15-30°C (59-86°F)
Fine/Suspended parcles
Detecon method Laser diracon
Operang range 0-1000 μg/m3
Precision
>100 μg/m3 , ± 10 %
<100 μg/m3 , ± 10 μg/m3
V. Product technical parameters
Item Content
Product dimensions 142x68x42 mm
Terminal block Maximum of 1.5 mm
2
Rated voltage 9-24VDC +/-10% Or use 12V1A power supply
Power consumpon
≦ 5W
Operating temperature 0°C– 50°C
Operating humidity 0%RH –95%RH (Non-condensing)
Storage -20°C– +70°C
Protection level IP20
Certification NCC,FCC/IC, CE, JRF
Accessories
Wall mount x 1, power supply x 1 (oponal), external temperature sensor cable x 1 (oponal),
wall plugs and wall screws, hex head screws, terminal male connectors, serial number scker x 1
VI. Sensor parameters
Total organic compounds
Detecon method Metal oxides
Operang range 0-60000ppb
Precision
± 15% (Data tested in
laboratory using alcohol)
Formaldehyde
Detecon method Electrochemistry
Operang range 0-5000 ppb
Precision ±15% @20-50°C
Carbon monoxide
Detecon method Electrochemistry
Operang range 0-500 ppm
Precision ±20 ppm
Ozone
Detecon method Electrochemistry
Operang range 0.4-10 ppm
Brightness
Operang range 0-10000 lux










