ELECTRICAL CHARACTERISTICS CURVES
For Negative Remote On/Off Logic
Figure 4: Turn-on transient at full rated load current (resistive
load) (10 ms/div). Vin=48V. Top Trace: Vout, 2.0V/div; Bottom
Trace: ON/OFF input, 2V/div
Figure 5: Turn-on transient at zero load current (10 ms/div).
Vin=48V. Top Trace: Vout: 2.0V/div, Bottom Trace: ON/OF
F
input, 2V/div
Figure 6: Output voltage response to step-change in loa
d
current (50%-25%-50% of Io, max; di/dt = 0.1A/µs; Vin is 24v).
Load cap: 10µF tantalum capacitor and 1µF ceramic capacitor.
Top Trace: Vout (50mV/div, 200us/div), Bottom Trace: Iou
t
(5
A
/div). Scope measurement should be made using a BN
C
cable (length shorter than 20 inches). Position the loa
d
between 51 mm to 76 mm (2 inches to 3 inches) from the
module
Figure 7: Output voltage response to step-change in load
current (50%-25%-50% of Io, max; di/dt = 0.1A/µs; Vin is 48v).
Load cap: 10µF tantalum capacitor and 1µF ceramic capacitor.
Top Trace: Vout (50mV/div, 200us/div), Bottom Trace: Iout
(5A/div). Scope measurement should be made using a BNC
cable (length shorter than 20 inches). Position the load
between 51 mm to 76 mm (2 inches to 3 inches) from the
module