Pinouts and Software Setup 54
The output frequency control Ixx69 specifies the maximum command output value that corresponds to the
maximum PFM Frequency.
I6826=3 ; MACRO IC Channel2 Output Mode Select. C PFM
M8000->Y:$7841C,8,16,S ; Supplementary Channel 2* Output C Command Value
; Min=0, Max= Calculated Ixx69
M8001->X:$7841D,21 ; Invert C Output Control. 0=no inversion, 1=invert
Testing The J9 PFM Output
Writing, directly to the suggested M-variable (i.e. M8000), values proportional to the calculated Ixx69,
produces the following corresponding frequencies:
M8000
PFM [KHz]
0
0
1213
11
2427