Installation Guide

Faucet leaks from tub spout/showerhead:
SHUT OFF WATER SUPPLIES.
Replace seats and springs–Repair
Kit RP4993. Check condition of lower O-rings and
replace if necessary RP14414. See Helpful Hints
1, 2, & 3.
If leak persists:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge RP46074.
See Helpful Hints 1, 2, 3 & 5.
Unable to maintain constant water temperature:
Replace valve cartridge RP46074 or follow
instructions in Helpful Hints 1, 2, 4 & 5.
Helpful Hints:
1. Before removing valve cartridge assembly for any
maintenance, be sure to note the position of the
rotational limit stop on the cap. The valve cartridge
assembly must always be put back in the same
position. BE SAFE! After you have nished the
installation, turn on valve to make sure COLD
WATER FLOWS FIRST.
2. To remove valve cartridge from body, shut o
water supplies and remove handle and bonnet
nut. Do not pry the valve cartridge out of the body
with a screwdriver. Place handle on stem and rotate
counterclockwise approximately 1/4 turn after the stop
has been contacted. Lift valve cartridge out of body.
3. To remove seats and springs, remove valve
cartridge. Separate cap assembly from the
housing assembly by rotating the cap assembly
counterclockwise 90
o
(degrees). Separate cap
and housing assemblies. Remove seats and
springs and replace. Place the largest diameter
of the spring into the seat pocket rst and then
press the tapered end of the seal over the spring.
Reassemble valve cartridge and replace in body
following instructions given in 1 above.
4. If the water in your area has lime, rust, sand or
other contaminants in it, your pressure balance
valve will require periodic inspection. The
frequency of the inspection will depend on the
amount of contaminants in the water. To inspect
valve cartridge remove it and follow the steps
in note 1 above. Turn the valve to the full mix
position and shake the cartridge vigorously. If
there is a rattling sound, the unit is functional and
can be reinstalled following instructions given in
note 1 above. If there is no rattle, replace valve
cartridge RP46074.
5. Push disc until fully seated. See pages 8 and 9
for more details.
To order replacement parts, visit
www.deltafaucet.com or call
1-800-345-DELTA (3358)
13/14 Series Maintenance
Cleaning and Care
Care should be given to the cleaning of this
product. Although its nish is extremely durable, it
can be damaged by harsh abrasives or polish. To
clean, simply wipe gently with a damp cloth and
blot dry with a soft towel.
11
WARNING: Scrubbing Bubbles
®
Bathroom Cleaner and Lysol
®
Basin Tub
and Tile Cleaner must not be used on the
clear knob handles and levers. Use of these
cleaners can result in cracked or severely
damaged handles. If overspray gets onto
the handles, immediately wipe them dry with
a soft cotton cloth.
!
72264 Rev. G