Installation Guide

SHUT OFF WATER SUPPLIES.
Consider the type and thickness of your
finished wall before placing your stringer
back plate.
Install the body (1) so the surface of the
finished wall is flush with the front of the
plasterguard (2) ± 3/8". Note: For
models with stops (3), plasterguard
must be flush or subflush 3/8" to
MultiChoice
®
Rough-In Installation
1
A.
B.
Distance (1) from the stringer (2) to the
front of the plasterguard is 2.8" (71 mm).
Distance (3) from the stringer (2) to the
front of the bonnet is 3.9" (99 mm).
finished wall.
Mount body using the two stringer
mounting holes (4) on the bracket.
Note: Remove cover (5) to access
mounting holes.
Make sure the word “UP” (6) is on top of
the valve body when installing.
IF A THIN WALL IS USED, be sure to
have the plasterguard behind the wall,
otherwise the wall should always be flush
with the front of the plasterguard. See in-
struction on the bag for thin wall mounting.
1
2
6
5
4
4
1
3
2
3