Exploded Parts
Page 3
206255 Rev. A
FOR RECESS MOUNT HOUSING: CONTROL BOXES #1, 6, 8.
INSTALLATION AND SET UP INSTRUCTIONS
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
Bracket
and
battery
holder not
required
for
hardwire
models
Flexible Sensor
Cord Conduit
(supplied on
Recessed Mount Box)
060829A
Screwdriver Stops with Check
060911A
Mechanical
Mixing Valve
060907A
Driver board
to be located
on this
bracket
Outlet
3/8” M.I.P.
Inlets 1/2”
Copper
Outlet
3/8” M.I.P.
Tempered Water
(By Others)
Inlet:
1/2” Copper
060576A
Screwdriver
Stop
Flexible Sensor
Cord Conduit
(supplied on Recessed
Mount Box)
060671A
3/4” NPS
Solenoid
Valve
060907A
Driver
board
to be
located
on this
bracket
Control Box #1
Control Box #6
Fig. 7
Fig. 8
Bracket
and
battery
holder not
required
for
hardwire
models
Flexible Sensor
Cord Conduit
(supplied on
Recessed Mount Box)
060907A
Driver board
to be located
on this bracket
Outlet
3/8” M.I.P.
Inlets 1/2”
Copper
Control Box #8
Fig. 9
061134A
Thermostatic Mixing Valve
and Gaskets
060829A
Screwdriver Stops with Checks
NOTE: 2.6”
MIN. clearance
to remove cap
COVERS
060073A
Screws (4/pkg) and driver bit for covers
060577A
12” Stainless Steel Cover
TMV Repair Kits
061135A
Gasket Kit only (3 pcs)
061137A
Adjustment Wrench
STEP 1. ROUGH IN
HARDWIRE Remove suitable knockout(s) in box(es) and insert cable bushing(s). See Fig. 6.
Note: Wires connecting between box(es) and from transformer must be protected from abrasion, and being
pulled at connections. They also may have to be fished through at a later stage of construction. Depending
on installation, the cable bushings included may be replaced by installer supplied 1/2” conduit. Rough-in
box as per Fig. 10a.
The transformer is to be installed in an adjacent accessible space. (Do NOT install the transformer inside
the control box.) Cable from the transformer to the controller may be roughed in at this time depending on
installation. Use cable which complies to local electrical codes for 1 amp load. No. 18 is usually sufficient.
HARDWIRE OR BATTERY If recessed box is supplied, rough in as per Fig. 10a. The most vandal resis-
tant installation is when the control box is as close to the bottom of the sink as feasible. For wall hung sink
installation, sensor conduit rough in should be directly under the basin to minimize sensor cord exposure.
Rough in drainage. Rough in water supply to 10” control box inlets and to spout connection. Finish walls.
If surface mount box as per Fig. 10b is supplied, attach to wall.
Knockouts
Cable Bushing
Fig. 6
STEP 2. FAUCET INSTALLATION
Connect 20” braided hose to spout inlet. Clean deck/sink surface where faucet will be mounted. Mount faucet to sink using nut(s) and
washer(s) provided. Installation of the single hole deck gasket (060564A) between the turret base and mounting surface is the recom-
mended assembly practice. Ensure that gasket is sitting flat on the deck and the turret is centered on the gasket. Use the same
procedure for installation of optional 4” or 8” deck plate package (060546A or 060547A). Mount the faucet to the sink using nut(s) and
washer(s) provided. Do not overtighten the nut (RP6087) or reposition the turret once installed, otherwise damage to the gasket may
result. Cutting or trimming of the gasket is not recommended. NOTE: If the gasket is trimmed or not installed, then use clear
silicone sealant between the faucet and lavatory to prevent water from leaking beneath lavatory.