FOR RECESS MOUNT HOUSING: CONTROL BOXES #1, 6, 8.
STEP 7. TEST FOR OPERATION
Test for operation. If unit does not work properly, see Troubleshooting Guide on
page 6.
STEP 8. MAKING ADJUSTMENTS
If adjustments are required. Note factory defaults for program shown in Quick
Reference Chart. Otherwise, replace the driver board housing cover as the
electronic product is ready for use.
INSTALLATION AND SET UP INSTRUCTIONS
Minimum Recommended
Distance 9" (229mm)
Sensing Zone
9" (228mm) default
1"
(25mm)
Operation Illustration
DRIVER BOARD QUICK REFERENCE CHART
AUTO TIMER (FAUCET SHUT-OFF)
Auto Timer is a safety mode in the event the sensor continually sees a target (i.e. tape on
the sensor). In this case, the faucet will stop after the pre-determined time period expires.
The Auto Timer values are 15, 30, 45, 60 and 75 seconds. The Auto Timer default value
is 45 seconds.
To adjust the Auto Timer feature, press and release the yellow pushbutton on the left
hand side of the digital light display. The current Auto Timer setting will then appear on
the light display. Press and release the same pushbutton continuously to scan through
the variable time periods (which are displayed as seconds on the digital light display).
To return to operation mode, do nothing for 5 seconds.
SENSOR RANGE (3-15”)
The sensor range is the maximum distance at which the user is detected. The sensor
range includes 3”, 6”, 9”, 12” and 15”. The sensor range default value is 9”. Note: Sensor
ranges +1” subject to environmental conditions.
To adjust the sensor range value, press and release the yellow pushbutton on the right
hand side of the digital light display. The current sensor range setting will then appear
on the light display. Press and release the same pushbutton continuously to scan through
the variable sensor ranges (which are displayed as inches on the digital light display).
To return to operation mode, do nothing for 5 seconds.
If you have any questions about the installation of this product or need help trouble-
shooting this product, please call Delta Commercial Technical Services at
1-800-387-8277.
Selection Adjustment Description
Factory Default Setting
Adjustment Range
Sensor Range
Auto Timer
(faucet shut-off)
You can set the distance at which the
sensor will detect hands in the wash area.
A safety mode in the event the sensor
continually sees a target.
9” from sensor
45 seconds
3” to 15” from sensor
15, 30, 45, 60 and 75
seconds