Exploded Parts
Page 2
205858 Rev. A
STEP 1. FAUCET INSTALLATION
Mount faucet to sink using the provided components in the following order - grey bottom
spacer, thin capacitance tab, lock nut (Fig. 1). NOTE: The black top spacer must be used
at all times between the spout and countertop, and the grey spacer must be used at
all times between the thin tab and deck. Ensure open side of bottom spacer faces up.
Thin tab faces away from sink. If cover plate is being used, it must be between the top
spacer and the deck. Use the same procedure for installation of optional 4” or 8” deck plate
package (061159A or 061160A). Mount the faucet to the sink using nut(s) and washer(s)
provided.
STEP 2. BATTERY BOX INSTALLATION
Mount battery box to wall under sink using the 4 supplied screws and anchors. Use 1/4”
drill for wall anchors. Be sure to install the box within the dimensions and orientation
provided so the hose and sensor cable will reach connections at faucet and battery
box. Refer to illustration (Fig. 2).
STEP 3. FLUSH SYSTEM
To flush supply line, assemble these components as shown (Fig. 3) and run water for one
minute. Shut off water supply. Attach aerator. NOTE: Do not connect supply to the
solenoid inlet until line is flushed directly out spout.
STEP 4. CONNECT WATER SUPPLY
Disassemble the components, reassemble the ones shown here (Fig. 4) supply line and
adapter to the bottom fitting on solenoid, polymer braided spout hose to the top fitting on
solenoid. Use Teflon
®
tape where indicated on adapter. Turn on water supply.
DO NOT SOLDER CONNECTIONS.
STEP 5. CONNECT PROXIMITY™ SENSOR
Run the white sensor wire out the bottom left of the box up to the spout along the polymer
braided hose up to the underside of the countertop (Fig. 2). Attach the female spade
terminal to the thin capacitance tab (Fig. 5). The thin tab may be bent to assist in making
the connection. ENSURE A TIGHT CONNECTION IS MADE. Use tie wraps (supplied) to
bind the white sensor wire along the polymer braided hose back to the control box (Fig. 2).
STEP 6. PREPARE SINK AREA
Before connecting the power - clean off counter and remove all objects from the sink.
STEP 7a. CONNECT POWER
IMPORTANT: ENSURE THAT WATER SUPPLY IS ON BEFORE PROCEEDING. WHEN
POWER IS FIRST APPLIED TO THE DRIVER BOARD, THE INSTALLER MUST
IMMEDIATELY STEP BACK AT LEAST 3 FEET FROM THE PROXIMITY SPOUT IN
ORDER TO ALLOW THE UNIT TO PROPERLY CALIBRATE.
BATTERY VERSION: Open the control box. Connect battery clip to battery pack. Install
four “C” batteries provided into the battery holder. 5 quick beeps 3 times will be generated
when power is first applied to the unit. At this stage, step back at least 3 feet from the
control box and spout in order to allow for proper calibration. Do not secure the lid until
after calibration.
HARDWIRE CALIBRATION: Install CSA and/or UL approved Calss 2 transformer or equivalent in a convenient
location or in a pipe chase. (Do NOT install the transformer inside the control box.) With the power off,
bring the 24 VAC supply wires to the box. Connect the 24 VAC supply to the 060683A conversion kit or battery
clip. Connect the 062029A ground wire kit (refer to 062029A instructions provided). Turn on power supply for
the transformer. 5 quick beeps 3 times will be generated when power is first applied to the unit. At this stage,
step back at least 3 feet from the control box and spout in order to allow for proper calibration. Do not
secure the lid until after calibration. The unit will turn on for approximately 10 seconds and proceed to shut off.
An additional 5 beeps once will then be heard indicating calibration is complete.
Bypass
Adapter
Braided
Polymer
Hose
INSTALLATION AND SET UP INSTRUCTIONS
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
Teflon
®
Tape
Fig. 3
Top Spacer
Thin Tab
Lock Nut
Spout
Fig. 1
Gasket
Bottom Spacer
7" (178 mm)
Max.
13" (331 mm)
Max.
Fig. 2
Tie
Wraps
Coverplate
Fig. 4
Braided
Polymer
Hose