Installation Sheet

063125A
High-Rise Spout
Assembly for
Proximity
060765A
Wrench
061198A
Single Hole Deck
Gasket (6/pkg)
061157A
Spacer
package
for Hi-Rise
Proximity
RP6087
Nut &
Washer
RP6001
Nut & Washer
061158A
Spacer package for
4” Lavatory Proximity
061156A
4” Lavatory Spout
Gasket (6/pkg)
063126A
4” Lavatory
Spout
Assembly for
Proximity
061206A
Proximity
Sensor
Module
Page 1
209493 Rev. A
Write purchase model number here for future reference
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as
items relating to ongoing maintenance suggestions and procedures are included.
060683A
24VAC to 6VDC Converter
061259A
Ground Wire Kit
(for hardwire models)
061047A
24VAC to 6VDC Converter with
Battery Backup
061256A
36” Sensor Module Extension Cable
209493 209493 209493 209493
209493 209493 209493 209493
www.specselect.com
OPTION LIST
TRANSFORMERS
060704A
Transformer 110 to 24 VAC 20VA
up to 5 Electronic Valves
060771A
Transformer 110 to 24 VAC 40VA
up to 10 Electronic Valves
060772A
Transformer 110 to 24 VAC 100VA
up to 25 Electronic Valves
DECK PLATES
061159A
4” Deck Plate & Hold-Down Pkg
061160A
8” Deck Plate & Hold-Down Pkg
060681A
Battery Holder
Model Number
591TPxxx0
591TPxxx1TR
591TPxxx8TR
590TPxxx0
590TPxxx1TR
590TPxxx8TR
Description
Battery Operated Surface Mount Box #0
Battery Operated Control Box #1 Trim
Battery Operated Control Box #8 Trim
Hard Wire Operated Surface Mount Box #0
Hard Wire Operated Control Box #1 Trim
Hard Wire Operated Control Box #8 Trim
Page #
2
4
6
8
10
12
COVER
060073A
Screws (4/pkg) and driver bit for covers
060577A
12” Stainless Steel Cover
TMV Repair Kits
061137A
Adjustment Wrench
063164A
Check Valves (2/pkg)
INSTALLATION AND SET-UP INSTRUCTIONS
063128A
Battery Box Assembly less driver
board and battery holder
060905A
Cover Gasket
060906A
Surface
Mount Housing
061252A
Dual
Driver Board
060909A
Screen Assembly
063131A
3/8” Comp Connect Nut
& Ferrile
063127A
Solenoid Valve with 3/8”
Compression Connectors
and Solenoid Holder
062032A
Braided Polymer Hose
060908A
Solenoid Holder
062032A
Braided Polymer Hose
59__TP__ __ __ __
RP6092
Nut & Washer
061159A
4” Deck Plate
& Holddown Pkg
061160A
8” Deck Plate
& Holddown Pkg
060638A
Vandal Resistant Laminar
Outlet with Antimicrobial
by Agion
®
1.5 GPM (5.7 L/min)
060640A
Vandal Resistant Flow
Control Aerator and Wrench
1.5 GPM (5.7 L/min)
061203A
Vandal Resistant Laminar
Outlet with Wrench
0.5 GPM (1.9 L/min)
061176A
Vandal Resistant Laminar
Outlet with Wrench
1.0 GPM (3.8 L/min)
061104A
Vandal Resistant Flow
Control Non-Aerating
Spray Outlet with Wrench
0.35 USGPM (1.3 L/min)
060642A - Optional
Flow Control Aerator
1.5 GPM (5.7 L/min)
NOTES:
For optimum performance of this product, the recommended system pressure is between
20 and 80 PSI static. This product will operate up to a maximum of 125 PSI static per
ANSI and CSA requirements. However, it is not recommended the pressure go above
80 PSI. Thermal expansion or leaking pressure reducing valves may require the use of
expansion tanks or relief valves to ensure your system never exceeds its maximum
intended pressure setting.
Control Box #0 and #1
Designed for routine 180°F (82°C) disinfection cycles up to 10 minutes.
Control Box #8
High temperature disinfection cycles not recommended for #8 control box as the thermo-
static mixing valve limits the higher temperature water flow output.
Use 3-conductor 18AWG wire between transformer and hardwire converter / driver
board earth ground.
Use Delta Commercial approved transformers and mount the transformer a minimum of
6” (152 mm) away from the Delta driver board enclosure.
Refer to Proximity Application Notes on SpecSelect for installation best practices,
proper grounding and wiring diagrams.

Summary of content (18 pages)