STEP 8. TEST FOR OPERATION
Test for operation. If OK, then close lid - Use caution not to damage wires or
components on electronic driver board. Route wires through notches/
openings in the box. See Fig 6. Secure lid using screws.
If faucet leaks from spout outlet:
SHUT OFF WATER SUPPLIES. Check proper solenoid connection. Replace
solenoid if problem persists.
If faucet exhibits very low flow:
A) Remove and clean Aerator, or
B) SHUT OFF WATER SUPPLY. Clean or replace Screen Assembly (1).
If unit does not work properly, see Trouble Shooting Guide on pages 16 & 17.
Installation should be in accordance with local plumbing and electrical codes.
FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION.
STEP 9. BASIC OPERATION AFTER CALIBRATION
Proximity
®
sensing technology works by creating an electrical field around a
conductor (the spout) and monitoring the change in capacitance that the conductor
undergoes. The change in capacitance (the ability to store an electrical charge) is
brought on by a 2nd conductor (a human body) entering the Proximity
®
field. As the
human hand enters and leaves the vicinity of the electrical field around the spout, the
solenoid is opened and closed accordingly. It is critical in the installation process that all electrical and mechanical connections be as tight and
rigid as possible, ensuring a smooth signal is carried from the driver board to the spout, and back again.
www.specselect.com
209493 Rev. A
Fig. 6
NOTE: Always make
sure driver board is in
place before inserting
the battery pack. Use
caution not to pinch
wires or damage
components on the
electronic driver board.
Trap jacket
of cable in
hole for strain
relief.
DO NOT
INSTALL
9V BATTERY
1
591TPxxx0 Battery Operated Surface Mount Box #0
INSTALLATION AND SET UP INSTRUCTIONS
After calibration, test the function of the product by placing your
hands within close proximity of the spout (ensuring hands are
moving as if washing hands). The solenoid will stay open
while hands are moving, then close once hands are removed
from the sensing zone.