User's Manual

Chapter 4 Parameters|
4-42 Revision August 2008, 03VE, SW V2.04
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory setting: 0
Settings Digit 4: decimal point number (0 to 3)
Digit 0-3: 40 to 9999
It is used digital setting method
Digital 4: decimal point number (0: no decimal point, 1: 1 decimal point and so on.)
Digit 0-3: 40 to 9999 (the corresponding value for the max. frequency).
U
F
H
01234
decimal point number
corresponding value
Digital
For example, if use uses rpm to display the motor speed and the corresponding value to the 4-
pole motor 60Hz is 1800. This parameter can be set to 01800 to indicate that the
corresponding value for 60Hz is 1800rpm. If the unit is rps, it can be set 10300 to indicate the
corresponding value for 60Hz is 30.0 (a decimal point).
00-06 Software Version
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory setting: Read Only
Settings Read Only
Display #.##
00-07 Password Input Unit: 1
Control
mode
VF VFPG SVC FOCPG TQRPG
Factory setting: 00
Settings 1 to 9998 and 10000 to 65535
Display 00~02 (times of wrong password)
The function of this parameter is to input the password that is set in Pr.00-08. Input the correct
password here to enable changing parameters. You are limited to a maximum of 3 attempts.
After 3 consecutive failed attempts, a blinking “PcodE” will show up to force the user to restart
the AC motor drive in order to try again to input the correct password.
When forgetting password, you can decode by setting 9999 and press button
twice.
Please note that all the settings will be set to factory setting.
00-08 Password Set
Unit: 1