Service manual

17
R-360EG
R-360ES
R-360EW
R-360EZ
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
STEPS OCCURRENCE CAUSE OR CORRECTION
1 Only pattern at "a" is broken. *Insert jumper wire J1 and solder.
2 Pattern at "a" and "b" are broken. *Insert the coil RCILF2003YAZZ between "c" and "d".
5) Make a visual inspection of the varistor. Check
for burned damage and examine the transformer
with a tester for the presence of layer short-
circuit (check the primary coil resistance which
is approximately 540 ± 20%). If any abnormal
condition is detected, replace the defective parts.
6) Reconnect all leads removed from components during testing.
7) Re-install the outer case (cabinet).
8) Reconnect the power supply cord after the outer case is installed.
9) Run the oven and check all functions.
2. Follow the troubleshooting guide given below, if the indicator does not light up after above check and
repairs are finished.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) To discharge the high voltage capacitor, wait for 60 seconds.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using
insulation tape.
6) After that procedure, re-connect the power supply cord.
7) Follow the troubleshooting guide given below for repair.
STEPS OCCURRENCE CAUSE OR CORRECTION
The rated AC voltage is not present between
1 the normal open terminal of the relay RY1 and Check supply voltage and oven power cord
the normal open terminal of the relay RY2.
2 The rated AC voltage is present at primary Low voltage transformer or secondary circuit defective.
side of low voltage transformer. Check and repair.
8) Disconnect the power supply cord, and then remove outer case.
9) Open the door and block it open.
10) To discharge the high voltage capacitor, wait for 60 seconds.
11) Reconnect all leads removed from components during testing.
12) Re-install the outer case (cabinet).
13) Reconnect the power supply cord after the outer case is installed.
14) Run the oven and check all functions.
D22
(J1)
RY2
a
b
c
d
VRS1