User's Manual

2
SPECIFICATIONS
GENERAL SPECIFICATIONS OUTPUT SPECIFICATIONS
Input Voltage 10.2V~13.8V Output Voltages programmable 0.9V~5.0V
Switching Frequency Typical 300KHz Voltage Accuracy Typical ±3% of Vo
Operating Temperature Typical - 40°C ~ + 80°C Output Current Maximum 6A
MTBF 7.6M hours Ripple & Noise 0.9V~2.5V 40 mVp-p
Size (Vertical Version) (1.20”×0.61”×0.46”) 30.5x15.5x11.7mm 3.3V~5.0V 50 mVp-p
Size (Horizontal Version) (1.20”×0.61”×0.48”) 30.5x15.5x12.3mm Weight 7.1g
PART NUMBERING SYSTEM
NC 12 S 0A0
H
06
P N
F
A
Product
Series
Input Voltage
Number of
outputs
Output
Voltage
Mounting
Output
Current
ON/OFF
Logic
Pin
Length
Option
Code
NC-
Non-isolated
Converter
12- 10.2~13.8V
S- Single
output
0A0-
programmable
H- Horizontal
V- Vertical
06- 6A
P- Positive
N-0.14”
R-0.118”
F- RoHS 6/6
(Lead Free)
A- Standard
Functions
MODEL LIST
Model Name Packaging Input Voltage Output Voltage Output Current
Efficiency
12Vin @ 100% load
NC12S0A0V06PNFA Vertical 10.2~ 13.8Vdc 0.9 V~ 5.0Vdc 6A 91% (5.0V)
NC12S0A0H06PNFA Horizontal 10.2~ 13.8Vdc 0.9 V~ 5.0Vdc 6A 91% (5.0V)
MECHANICAL DRAWING
VERTICAL
HORIZONTAL
CONTACT:
www.delta.com.tw/dcdc
USA:
Telephone:
East Coast: (888) 335 8201
West Coast: (888) 335 8208
Fax: (978) 656 3964
Email:
DCDC@delta-corp.com
Europe:
Telephone: +41 31 998 53 11
Fax: +41 31 998 53 53
Email:
DCDC@delta-es.tw
Asia & the rest of world:
Telephone: +886 3 4526107 ext. 6220
Fax: +886 3 4513485
Email:
DCDC@delta.com.tw
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any
infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any
patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.