Specification Sheet

Page 4.C.1DSP–DEMD-600 Page 4.C.1
L
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.
Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.
DSP–DEMD-600 Rev. A
DEMD Series – Thermostatic Electronic
Lavatory Faucets (Infrared)
BELOW DECK
BATTERY
PACK
DEMD-611LF SERIES (BATTERY OPERATED)
TYPICAL INSTALLATION
HARDWIRE CONVERSION OF DEMD-611LF SERIES
A
One 060958A DEMD plug in power supply,
output 9VDC
B
One 060704A hardwire 20VA transformer
(120VAC to 24VAC)
plus
One 060974A DEMD converter
(24VAC to 9VDC)
Requires SEPARATE order of either:
OR
SPECIFICATION: (example)
Deck mount ASSE 1070 thermostatic
electronic lavatory faucet with above deck
electronics
Mixing handle to adjust temperature
Adjustable comfort limit stop
Chrome finish
Sensor detects user’s hand to activate
water flow
6x 1.5V “AA” Batteries (included)
15 second maximum run time
Adjustable sensor range
Red light indicator blinks when battery is low
o DEMD-611LF
0.66 gpm (2.5 L/min) spray outlet
(0.17 gal/cycle, 0.64 L/cycle max.
based on 15 second run time).
o DEMD-611-10LF
1.0 gpm (3.8 L/min) spray outlet
(0.25 gal/cycle, 0.94 L/cycle max.
based on 15 second run time).
OPERATION
Sensing Range:
Factory set to 6.6" ± 1.5" (168 mm ± 40 mm)
Adjustable with optional remote control
Run Time:
Hands free (touchless) on/off activation
Water flows when sensor activated
Water flow stops upon de-activation
Operates with a 15 second maximum
run time
Inlet Water Pressure Range: 20 - 125 psi
Supply Pressure Differential: Pressure
difference between hot & cold supply should
not exceed ±20%
Cold Water Inlet Range: 39ºF - 80ºF
(4ºC - 27ºC)
Hot Water Inlet Range: 120ºF - 180ºF
(49ºC - 82ºC)
Outlet Temperature Comfort Stop Range:
Fixed or adjustable from cold to 120°F
(49°C) max. Factory set to 105ºF (40.5°C).
Temperature Differential: Hot inlet
temperature to be a minimum of +27°F
(+17°C) hotter than the desired outlet
temperature
OPTIONAL ACCESSORIES (Order Separately)
o 060967A
Remote Control (Optional)
Allows adjustment of sensor range, maximum run time,
delayed close time, temporary shutoff for cleaning and
factory settings reset.
o 060585A
Optional 4" coverplate (no anti-rotation)
Approvals:
IAPMO certified
Complies to ASME A112.18.1/CSA B125.1,
CSA B125.3 and ASSE 1070
Indicates compliance to
ICC / ANSI A117.1 – Valve actuation only
Verified compliant with 0.25% weighted
average Pb content regulations
(Contact Delta Representative for State and/or
Local Approvals.)
Note: Measurements may vary ± 6mm (0.25")
Refer to www.specselect.com for individual models.
Note: Use this page as a product submittal sheet.
149 mm
(5.9")
50 mm
(2.0")
99 mm
(3.9")
186 mm
(7.3")
Sensor
45°
87 mm
(3.4")
79 mm
(3.1")
Max. deck thickness
with Escutcheon
45 mm (1.8")
Less Escutcheon
51 mm (2.0")
Min. deck thickness
2 mm (0.09")
3/8" Compression
Fittings
For sensor clearance:
25 mm (1") maximum
sink lip height from deck
For sensor clearance:
20 mm (0.8") maximum
sink lip height from deck
5 mm
(0.2")
60 mm
(Ø 2.4")
28 mm
(Ø 1.1")
Temperature
Adjustment
Handle
Escutcheon
Hole through
sink/deck
28 mm (1.1") min.
38 mm (1.5") max.
762 mm (30")
maximum
from deck to
battery pack
149 mm
(5.9")
50 mm
(2.0")
99 mm
(3.9")
186 mm
(7.3")
Sensor
45°
87 mm
(3.4")
79 mm
(3.1")
Max. deck thickness
with Escutcheon
45 mm (1.8")
Less Escutcheon
51 mm (2.0")
Min. deck thickness
2 mm (0.09")
3/8" Compression
Fittings
For sensor clearance:
25 mm (1") maximum
sink lip height from deck
For sensor clearance:
20 mm (0.8") maximum
sink lip height from deck
5 mm
(0.2")
60 mm
(Ø 2.4")
28 mm
(Ø 1.1")
Temperature
Adjustment
Handle
Escutcheon
Hole through
sink/deck
28 mm (1.1") min.
38 mm (1.5") max.
762 mm (30")
maximum
from deck to
battery pack
149 mm
(5.9")
50 mm
(2.0")
99 mm
(3.9")
186 mm
(7.3")
Sensor
45°
87 mm
(3.4")
79 mm
(3.1")
Max. deck thickness
with Escutcheon
45 mm (1.8")
Less Escutcheon
51 mm (2.0")
Min. deck thickness
2 mm (0.09")
3/8" Compression
Fittings
For sensor clearance:
25 mm (1") maximum
sink lip height from deck
For sensor clearance:
20 mm (0.8") maximum
sink lip height from deck
5 mm
(0.2")
60 mm
(Ø 2.4")
28 mm
(Ø 1.1")
Temperature
Adjustment
Handle
Escutcheon
Hole through
sink/deck
28 mm (1.1") min.
38 mm (1.5") max.
762 mm (30")
maximum
from deck to
battery pack
WITHOUT
ESCUTCHEON
WITH
ESCUTCHEON