Instruction Manual

DOP-107H
High colorControllableUser-friendly
Delta Electronics Inc,
No.18, Xinglong Rd., Taoyuan City
33068, Taiwan
Instruction Sheet
(1) General precautions
Thank you for purchasing this product. This DOP-107H instruction sheet provides information for the DOP-107H series
HMI. Before using this product, read through this instruction sheet carefully to ensure the correct use of the product.
Keep this sheet handy for quick reference whenever needed. Before finishing reading this sheet, follow the following
instructions.
Install the product in an indoor environment which is free of vapor, corrosive and inflammable gas.
Refer to the wiring diagram when connecting the wires.
Ensure this product is correctly grounded. The grounding method must comply with the national standard
guidelines (refer to NFPA 70: National Electrical Code, 2005 Ed.).
Do not change the wiring when power is on.
Do not touch the power supply when power is on, or it may cause electric shock.
When the HMI displays a low power notification and requires a battery change, contact the local distributor or
Delta Customer Service Center for the replacement. Do not change the batteries by yourself.
If you have any inquiry during operation, contact the local distributors or Delta Customer Service Center. The instruction
sheet may be revised without prior notice. Contact our distributors or download the latest version from the Delta website
(http://www.deltaww.com).
(2) Safety precautions
Pay attention to the following safety precautions during installation, wiring, operation, maintenance, and inspection.
Installation
Comply with the instructions specified in the user manual for installation, or it may cause damage to
the equipment.
Avoid exposing the product to an environment containing vapor, corrosive gas, inflammable gas, or
other foreign matter, or it may cause product damage, electric shock, fire, or explosion.
Do not install the HMI in an environment where the ambient temperature exceeds the specified
range, or it may cause abnormal operation or product damage.
This product has the approval of KC Class A (for commercial devices), which is designed for
commercial or industrial use, rather than for domestic use. If you have unintentionally purchased or
sold the HMI products, replace them with products having the approval of KC Class B (for domestic
use).
Do not install the HMI to the machinery that may cause personnel injury, equipment damage, or
emergency stop.
Wiring
Connect the ground terminals to class-3 ground system. Ground resistance should not exceed 100Ω.
Improper grounding may cause communication error, electric shock, or fire.
Do not connect other wire rods to extend the cable length, or it may cause poor communication or
malfunction.
Operation
Program the HMI screens with the DOPSoft software. If the HMI is not well-programmed, it may
cause abnormal operation. To avoid personnel injury or equipment damage during operation, ensure
the communication error occurring between the HMI and controller or equipment does not cause
malfunction when programming the HMI screens.
Back up the programmed HMI screens and programs to avoid unexpected data loss.
Place the HMI on a flat surface or hang it with the hook on its back to prevent it from falling and thus
crashing.
Do not change the wiring when power is on, or it may cause electric shock or personnel injury.
Do not touch the panel with sharp objects, or it may make a dent in the panel, resulting abnormal
operation of the HMI.
Maintenance and inspection
Do not touch the internal parts of the HMI, or it may cause electric shock or product damage.
Do not touch the wiring terminals within 10 minutes after turning off the power. The residual voltage
may cause electric shock.
Wiring method
The voltage applied to the HMI should not exceed the specified range, or it may cause product
damage, electric shock, or fire.
If any cable removal is forced, check the connection again before resuming the operation.
Communication wiring
Ensure the ground circuit is correct to avoid poor communication.
To prevent excessive interference from causing abnormal operation of the HMI, place the
communication cable, all power cables, and the motor power cable in separate conduits.
(3) Model explanation
(1)
DOP
(2)
1
(3)
07
(4)
HS
(5)
4
(6)
6
(7)
5
(8)
ZM
(1)
DOP: Delta Operation Panel (HMI)
(2)
1: 100 series HMI
(3)
07: 7.0"
(4)
HE: Ethernet
HS: standard
(5)
4: WVGA
(6)
Code
MPG
SD
15 Keys
21 Keys
2
6
7
(7)
5: 5 m
A: 10 m
(8)
ZM / ZD: D-SUB connector
(4) Description of each part
DOP-107HE42x / DOP-107HE46x / DOP-107HS42x / DOP-107HS46x (front view)
DOP-107HE42xZM / DOP-107HE46xZM (front view)
DOP-107HE47xZD (front view)
1
Power indicator
4
Auxiliary keyboard
2
Emergency stop switch
5
Operation / display area
3
MPG
-
-
DOP-107HE42x /DOP-107HE42xZM / DOP-107HE46x / DOP-107HE46xZM / /DOP-107HE47xZD / DOP-107HS42x /
DOP-107HS46x (rear view)
1
3-position operation switch
2
Bus
DOP-107HE42x / DOP-107HE42xZM / DOP-107HE46x / DOP-107HE46xZM / DOP-107HE47xZD / DOP-107HS42x /
DOP-107HS46x (bottom view)
1
USB slave
2
SD card
(5) Installation environment
Before installation, this product must be kept in the shipping carton. In order to retain the warranty coverage and for
maintenance, follow the following instructions for storage. While the product is temporarily not in use:
Store the product in a dust-free and dry place.
Store the product in an ambient temperature of -10°C to +60°C (14°F to 140°F).
Store the product in a relative humidity range of 10% to 90% RH (non-condensing).
Avoid storing the product in an environment containing corrosive gas and liquids.
Properly wrap the product and place it on a shelf or platform.
The suitable installation environment should be a location that is free of devices that generate excessive heat,
water, vapor, dust and oily dust, corrosive and inflammable gas and liquids, airborne dust and metal particles,
vibration, and electronic interference.
This product must be used at an altitude below 2,000 m (6,561.68 feet).
(6) Wiring
D-SUB connector
Pin assignment for DOP-107HE42xZM / DOP-107HE46xZM / DOP-107HE47xZD series (D-SUB)
25-pin D-SUB
Function
1
LAN RD+
2
LAN RD-
3
Reserved
7
Emergency stop – NO(A)
8
Emergency stop – NO(A)
9
Emergency stop – NC(B)
10
Emergency stop – NC(B)
13
0Vdc input (use SELV power supply, isolated from MAINS by double insulation)
14
LAN TD+
15
LAN TD-
18
external power input of MPG
20
output point A of MPG
21
output point B of MPG
22
3-position operation switch – NO(A)
23
3-position operation switch – NO(A)
25
24Vdc input (use SELV power supply, isolated from MAINS by double insulation)

Summary of content (8 pages)