Specification Sheet

Submitted Model No.: _______________________________________________
Specific Features: __________________________________________________
R4707
ROUGH-IN KITS
Two Handle Diverter Roman Tub
Rough-In Kit
Flexible Deck or Ledge Mount
Adjustable Rough-In for Thin or Thick
Deck Installations
Installed Before Mud and Tile Applied in
Thick Deck Situation
Four Hole Installation
16" (406 mm) Maximum Widespread
(without using additional tubing)
Temperature and Volume Controlled
with Handles
Trim Kit Must Also be Ordered to
Complete Installation
COMPLIES WITH:
ASME A112.18.1
CSA B125
ROUGH-IN KIT
STANDARD SPECIFICATIONS:
Washerless.
Four hole installation.
5/8" O.D. copper supply inlet/outlet tubes–R4707
outlet tubes are corrugated copper.
Widespread with 16" (406 mm) maximum without
using additional tubing.
Flexible deck or ledge mount installation.
Solid fabricated brass end valves and spout body.
• Control mechanism shall be of the rotating cylinder
type with stainless steel plate and 180° rotation,
with replaceable non-metallic seats operating in
stainless steel lined sockets.
Hot and cold stems are interchangeable.
Temperature and volume controlled with handles.
All operating parts shall be replaceable from the top.
NOTE: Trim kit must also be ordered to complete
installation. Refer to separate trim kit specifications to
determine the best kit for your situation.
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only.
Tee
Inlet Tube
Spout
Adapter
5/8" O.D.
Copper Tube
Inlet Tube
Finished Deck (Standard) Installation
2 1/2"
(63.5 mm)
Max. Deck
Thickness
3" (76 mm) Min.
From Wall
5"
(127 mm)
Min.*
From Wall
8" (203 mm) Min.*
1 1/2" (38 mm) Dia.
Rough Deck (Thick Tile) Installation
*16" (406 mm) Maximum
Without Using Additional Tubing.
24" (610 mm)
Braided
Leader Hose
Corrugated Outlet Tubes
18" (457 mm) Max.
1 3/4" (45 mm)
From Finished
Surface
15/16"
(32 mm)
From
Finished
Surface
Tee
Inlet Tube
Spout
Adapter
5/8" O.D.
Copper Tube
Inlet Tube
2 1/2"
(63.5 mm)
Max. Deck
Thickness
3" (76 mm) Min.
From Wall
5"
(127 mm)
Min.*
From Wall
8" (203 mm) Min.*
2" (51 mm) Dia.
*16" (406 mm) Maximum
Without Using Additional Tubing.
24" (610 mm)
Braided
Leader Hose
Corrugated Outlet Tubes
18" (457 mm) Max.
1 3/4" (45 mm)
From Finished
Surface
15/16"
(32 mm)
From
Finished
Surface
Hand Spray
Support
Assembly
Hand Spray
Support
Assembly