User Manual

9 Register Reference
plot.
F31:5
15883
D15882
-
%MD31.5
UDINT
-
Reserved
F31:6
15885
D15884
-
%MD31.6
UDINT
-
Reserved
F31:7
15887
D15886
-
%MD31.7
UDINT
-
Reserved
RMC70 Registers, Files 32-39: Plot Configuration Registers
The following files contain the Plot Configuration registers. See the Reading Plots with a Host
Controller topic for details on how some of them can be used.
AB
DF1,CSP
Address
Modbus
TCP,RTU
Address
FINS
Address
External
Data
Type
Internal
IEC
Address
Internal
Data
Type Access Register Name
Plot 0
F32:0
16385
D16384
REAL
%MD32.0
UDINT
not
directly
Plot Flags
These bits should
not be accessed
directly.
0
Reserved (Write
Only)
1
Trigger (Write
only)
2
Rearm (Write
Only)
3
Read Active
(Read Only)
4
Trigger Enabled
(Read Only)
F32:1
16387
D16386
REAL
%MD32.1
UDINT
Read/Write
Plot Samples (e.g.
1000)
F32:2
16389
D16388
REAL
%MD32.2
REAL
Read/Write
Plot Sample Period
(seconds)
F32:3
16391
D16390
REAL
%MD32.3
DINT
Read/Write
Plot Axis Owner
0-3, -1 = none
F32:4
16393
D16392
REAL
%MD32.4
REAL
Read/Write
Plot Trigger Position
%, 0-100, -1 =
auto rearm
F32:5
16395
D16394
REAL
%MD32.5
UDINT
Read/Write
Plot Trigger Type
0-
7
Trigger Type
(0=none,
1=motion
command)
8-
23
Depends on
trigger type
Motion
Commands:
8-
11
Axis 0-3 bits,
if all zero,
deltamotion.com 1071