User Manual
9 Register Reference
Bits 12-23
File
Plot 1
F33:0
16897
D16896
REAL
%MD33.0
UDINT
not
directly
Plot Flags
These bits should
not be accessed
directly.
0
Reserved (Write
Only)
1
Trigger (Write
only)
2
Rearm (Write
Only)
3
Read Active
(Read Only)
4
Trigger Enabled
(Read Only)
F33:1
16899
D16898
REAL
%MD33.1
UDINT
Read/Write
Plot Samples (e.g.
1000)
F33:2
16901
D16900
REAL
%MD33.2
REAL
Read/Write
Plot Sample Period
(seconds)
F33:3
16903
D16902
REAL
%MD33.3
DINT
Read/Write
Plot Axis Owner
0-3, -1 = none
F33:4
16905
D16904
REAL
%MD33.4
REAL
Read/Write
Plot Trigger Position
%, 0-100, -1 =
auto rearm
F33:5
16907
D16906
REAL
%MD33.5
UDINT
Read/Write
Plot Trigger Type
0-
7
Trigger Type
(0=none,
1=motion
command)
8-
23
Depends on
trigger type
Motion
Commands:
8-
11
Axis 0-3 bits,
if all zero,
then use
Axis Owner
12-
23
Reserved
F33:6
16909
D16908
REAL
%MD33.6
-
-
Reserved
F33:7
16911
D16910
REAL
%MD33.7
-
-
Reserved
F33:8
16913
D16912
REAL
%MD33.8
REAL
Read Only
Plot ID
F33:9
16915
D16914
REAL
%MD33.9
REAL
Read Only
Plot State
0 = not triggered, 1
= capturing, 2 =
deltamotion.com 1073