User Manual

RMC70/150 and RMCTools User Manual
Data Sets 0-15.
Bits 0-11
Element
Bits 12-23
File
Plot 5
F37:0
18945
D18944
REAL
%MD37.0
UDINT
not
directly
Plot Flags
These bits should
not be accessed
directly.
0
Reserved (Write
Only)
1
Trigger (Write
only)
2
Rearm (Write
Only)
3
Read Active
(Read Only)
4
Trigger Enabled
(Read Only)
F37:1
18947
D18946
REAL
%MD37.1
UDINT
Read/Write
Plot Samples (e.g.
1000)
F37:2
18949
D18948
REAL
%MD37.2
REAL
Read/Write
Plot Sample Period
(seconds)
F37:3
18951
D18950
REAL
%MD37.3
DINT
Read/Write
Plot Axis Owner
0-3, -1 = none
F37:4
18953
D18952
REAL
%MD37.4
REAL
Read/Write
Plot Trigger Position
%, 0-100, -1 =
auto rearm
F37:5
18955
D18954
REAL
%MD37.5
UDINT
Read/Write
Plot Trigger Type
0-
7
Trigger Type
(0=none,
1=motion
command)
8-
23
Depends on
trigger type
Motion
Commands:
8-
11
Axis 0-3 bits,
if all zero,
then use
Axis Owner
12-
23
Reserved
F37:6
18957
D18956
REAL
%MD37.6
-
-
Reserved
F37:7
18959
D18958
REAL
%MD37.7
-
-
Reserved
F37:8
18961
D18960
REAL
%MD37.8
REAL
Read Only
Plot ID
F37:9
18963
D18962
REAL
%MD37.9
REAL
Read Only
Plot State
1080 Delta Computer Systems, Inc.