User Manual

9 Register Reference
0 = not triggered, 1
= capturing, 2 =
complete
F37:10
18965
D18964
REAL
%MD37.10
DINT
Read Only
Plot Captured
Samples
Number of plot
samples captured.
Only applies for Plot
State > 0.
F37:11
18967
D18966
REAL
%MD37.11
DINT
Read Only
Plot Sample 0 Time
Time that first plot
sample was
captured. In control
loops since
controller startup
(low 24 bits). Only
applies for Plot
State > 0.
F37:12
18969
D18968
REAL
%MD37.12
DINT
Read Only
Plot Trigger Time
Time that plot
trigger occurred. In
control loops since
controller startup
(low 24 bits). Only
applies for Plot
State > 0.
F37:13
18971
D18970
REAL
%MD37.13
DINT
Read Only
Plot Trigger Index
Index of the plot
sample at which the
plot trigger
occurred. Only
applies for Plot
State > 0.
F37:14-
15
18973-
18975
D18972-
D18974
-
%MD37.14-
15
-
-
Reserved
F37:16-
31
18977-
19007
D18976-
D19006
REAL
%MD37.16-
31
DWORD
Read/Write
Plot Data Sets 0-15
Addresses
Files %MDn:16-31
contain the
Addresses for plot
Data Sets 0-15.
Bits 0-11
Element
Bits 12-23
File
Plot 6
F38:0
19457
D19456
REAL
%MD38.0
UDINT
not
directly
Plot Flags
These bits should
not be accessed
directly.
0
Reserved (Write
Only)
1
Trigger (Write
deltamotion.com 1081