9 Register Reference
15
Plot (1-16)
16-
23
Reserved
F95:1
48643
E0_15874
REAL
%MD95.1
UDINT
Read Only
Maximum Plots (8)
This read-only value
indicates how many
plots can be defined
at once.
F95:2
48645
E0_15876
REAL
%MD95.2
UDINT
Read Only
Maximum Samples
(16)
This read-only value
indicates how many
samples sets can be
captured
simultaneously per
plot.
F95:3
48647
E0_15878
REAL
%MD95.3
UDINT
Read Only
Maximum Samples at
Once (128)
This read-only value
indicates how many
total different
samples can be
allocated across all
plots.
F95:4
48649
E0_15880
REAL
%MD95.4
UDINT
Read Only
Maximum Elements
(12,582,912)
This read-only value
indicates how many
total data points can
be captured. This is
spread out among
the number of
allocated plots and
samples per plot.
F95:5
48651
E0_15882
-
%MD95.5
UDINT
-
Reserved
F95:6
48653
E0_15884
-
%MD95.6
UDINT
-
Reserved
F95:7
48655
E0_15886
-
%MD95.7
UDINT
-
Reserved
RMC150 Registers, Files 96-103: Plot Configuration Registers
The following files contain the Plot Configuration registers. See the Reading Plots with a Host
Controller topic for details on how some of them can be used.
n = plot # (0-7)
f = 96 + n
b = 512 x n
AB
DF1,
CSP
Address
Modbus
TCP,
RTU
Address
FINS
Address
External
Data
Type
Internal
IEC
Address
Internal
Data
Type Access Register Name
Plot n
Ff:0
49153 +
E0_16384
REAL
%MDf.0
UDINT
not
Plot Flags
deltamotion.com 1113