User Manual
RMC70/150 and RMCTools User Manual
How to Find:
Axes Status Registers Pane, All tab: Control
Axes Status Registers Pane, All tab: Pressure/Force Control
Data Type:
REAL
Units:
% of maximum control output
Description
The Pressure/Force Feed Forward Term is the portion of the control output contributed by
the Pressure/Force Feed Forward Term. The Pressure/Force Feed Forward Term is useful
for troubleshooting when included in a plot.
See Pressure/Force Feed Forward
Gain for more details.
9.2.1.6.6. Pressure/Force Rate Feed Forward Term
Type:
Axis Status Register
RMC70 Address:
Primary Input: %MDn.41, where n = 8 + the axis number
Secondary Input: %MDn.52, where n = 8 + the axis number
RMC150
Address:
Primary Input: %MDn.41, where n = 8 + the axis number
Secondary Input: %MDn.52, where n = 8 + the axis number
System Tag:
Pressure Input: _Axis[n].PrsRateFFwdTerm, where n is the axis
number
Force Input: _Axis[n].FrcRateFFwdTerm, where n is the axis
number
How to Find:
Axes Status Registers Pane, All tab: Control
Axes Status Registers Pane, All tab: Pressure/Force Control
Data Type:
REAL
Units:
% of maximum control output
Description
The Pressure/Force Rate Feed Forward Term is the portion of control output contributed
by the Pressure/Force Rate Feed Forward Gain. The Pressure/Force Rate Feed Forward
Term is useful for troubleshooting when included in a plot.
See the Pressure/Force Rate Feed Forward
topic for more details.
9.2.1.7. Target
9.2.1.7.1. Command Position
Type:
Axis Status Register
RMC70 Address:
%MDn.56, where n = 8 + the axis number
RMC150 Address:
%MDn.56, where n = 8 + the axis number
System Tag:
_Axis[n].CmdPos, where n is the axis number
How to Find:
Axes Status Registers Pane, Basic tab
Data Type:
REAL
Units:
pu
Description
878 Delta Computer Systems, Inc.