Installation Guide

19
Symptom: Alignment Recommended Action
1. The top of the glass panel is tilted away from the wall jamb. Remove the glass panel from the top track and raise the roller on the
bracket closest to the wall jamb.
2. The bottom of the glass panel is tilted away from the wall jamb. Remove the glass panel from the top track and lower the roller on the
bracket that is closest to the wall jamb.
3. The glass panel does not touch the bumper. Determine whether glass panel top or bottom is closer to the wall, and
then adjust the roller closest to the wall per #1 or #2 above.
4. The top track is cut too short. New track kit must be purchased and top track must be cut correctly.
See steps 20-23.
5. The bottom track is miscut. Seal as directed to ensure watertight seal. See steps 18 and 19.
If additional sealant insufficient, new bottom track may be required.
Symptom: Water Leaks Recommended Action
1. Water leaks between panels When showering, make sure the inside panel is closest to the
showerhead wall.
2. Water leaks between wall jamb and the glass panel. For adjustment, see Symptom: Alignment.
3. Water leaks under the bottom track. Check for proper silicone sealant application. See steps 37 and 38.
Apply more silicone sealant as needed.
Symptom: Operation (open/close) Recommended Action
1. The outside panel is difficult to move. a. Ensure sufficient clearance exists between the bottom track and the
glass panel. If needed, lower the rollers to the next hole.
b. Ensure the panel is properly engaged over the bottom track. See
steps 29 and 30.
c. Ensure the rollers are properly installed.
d. Clean any debris in the top track where the rollers operate.
2. The inside panel is difficult to move. a. Ensure sufficient clearance exists between the bottom track and the
glass panel. If needed, lower the rollers to the next hole.
b. Ensure the inside center guide is properly secured with self-tapping
screws. See step 36.
c. Ensure the rollers are properly installed.
d. Clean any debris in the top track where the rollers operate.
Symptom: Maintenance Recommended Action
1. Excess noise or vibration. a. Check all fasteners and re-tighten as necessary.
b. Ensure bushings (CC) are installed in glass.
2. Track kit discoloration. Carefully review and follow Care and Cleaning instructions.
TROUBLESHOOTING