Specification Sheet
Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation.
Dimensions are for reference only. See current full-line price book or www.specselect.com for finish options and product availability.
Page 2.C.12 DSP–T17TH1 Rev. E
MultiChoice
®
Universal
Thermostatic Tub and Shower
Refer to www.specselect.com for individual models. Note: Use this page front and back as a product submittal sheet.
(7.0") Ø
178mm
(36.0")
910mm
OPTIONAL
TO FLOOR
(4.0")
102mm
(6.0")
152mm
70mm
(2.75")
(36.0")
910mm
OPTIONAL
VALVE BODY
C
L
51mm
(2.0")
HOT & COLD
INLETS
STOPS
R10000-UNWS
METAL LEVER
HANDLE
Approvals:
• ASME A112.18.1/CSA B125.1
•
Indicates compliance to
ICC/ANSI A117.1
• Thermostatic Valve ASSE 1016
• Handshower back flow protection provided by
two integral certified check valves in series,
which operate independently, ASME A112.18.3
( Contact Delta Representative for State and/or
Local Approvals.)
Note: Measurements may vary ± 6mm (0.25")
P/B VALVE INLETS:
1/2" Universal inlets accept 1/2" copper,
1/2" Iron pipe, PEX or CPVC adaptors
1/2" Male thread inlets/outlets
FLOW RATE vs PRESSURE
2.5
3
3.5
2
1.5
1
.5
00
0
1
2
3
4
5
6
7
8
9
10 20 30 40 50 60 70 80
10
11
12
13
Shower Outlets
No. 2 & No. 3
Line Pressure (psig)
FLOW
(L/min)
FLOW
(gpm)
No. 5
Shower Outlet Flow Rates
FRONT VIEW SIDE VIEW
R10000-UNWS Rough-In
with
T17TH135 Trim
FLOW RATE vs PRESSURE
6.5
7
7.5
8
5.5
6
5
4
4.5
3.5
3 11.5
13
20 30 40 50 60 70 80
Line Pressure (psig)
FLOW
(L/min.)
FLOW
(gpm)
14.5
16
17.5
19
20.5
22
23.5
25
26.5
28
29.5
Tub Filler Flow Rates
®
PAUSE WARNING FOR SHOWER #5
Plumbing Codes require that showerheads and handshowers provide a small but continuous flow
of water (trickle) when in “PAUSE” mode. Because of this continuous flow, in certain circumstances
pressure variations in the water line and/or changes in the position of the shower temperature control
handle while in “PAUSE” mode could result in dramatic changes to the temperature of the water when
the shower head or hand shower is returned to the “ON” position.
ALWAYS point the shower head away from yourself when returning to the “ON” position and feel the
water with your hand before resuming your shower to ensure the water flow is not too hot or too cold.
DO NOT allow children or others who might not understand this warning to use the “PAUSE” function.
DSP–T17TH1 Rev. E