Operating Guide

104438 Rev. A
Installation
4
6
Installation and Adjustment of the Rotational Limit Stop
Place the rotational limit stop (1) in
volume
handle (2) and rotate to the mixed
position (if
required). DO NOT SECURE WITH
SCREW.
Turn on water supplies; let the
water
run until
both hot and cold water is as hot/
cold as
possible. Place thermometer in a plastic tumbler,
and hold the tumbler in the water stream.
Record the temperature reading.
If the water temperature is above 120°F, remove
and rotate the limit stop (1) clockwise one tooth
for every 4°F - 6°F (approximate) change in
temperature. If water temperature is cooler than
desired, rotate the limit stop counterclockwise.
IMPORTANT: The rst position of the Rotational
Limit Stop (the Limiter) is the position that
restricts the rotation of the stem the most and is
at the maximum clockwise setting. According to
industry standards, the maximum allowable
temperature of the water exiting from the valve is
120
o
F. This temperature may vary in your local
area. The Rotational Limit Stop may need to be
readjusted if the inlet water temperature changes.
For instance, during the winter, the cold water
temperature is colder than it is during the summer
which could result in varying outlet temperatures.
Typical temperature for a comfortable bath or
shower is between 90
o
–110
o
F.
Secure temperature control knob (1) with screw
(2). See next step (D) for securing temperature
control cover (3).
Snap temperature control cover over temperature
control knob by rst aligning smaller tab (1) on
cover with receiving slot (2) on temperature knob.
Swing larger tab (3) to engage with snap feature
(4). Note: If dis-assembly is required, reverse
this motion, disengaging larger tab (3) from snap
feature (4) rst.
D.
4
2
1
3
B.
Hotter
Colder
1
A.
1
C.
1
2
3
2