Installation Guides

Installation
2
Showerhead and Tub Spout Installation
4
FOR TUB SPOUT INSTALLATION:
Refer to the installation instructions supplied with your spout. Do not connect deck mount spouts to
in-wall valves. Do not use hand showers connected in lieu of a tub spout to a tub/shower valve. Do not
use PEX tubing for tub spout drop.
Slip-On Installation
The copper tube (1) must be 1/2” nominal
copper. Important: If it is necessary to cut the
copper tube, the end must be chamfered free of
burrs to prevent cutting or nicking O-ring inside
the spout. Slide spout over copper tube ush
with the nished tub or wall surface. Tighten set
screw (2), but do not overtighten.
Iron Pipe Installation
Install threaded pipe nipple (1) to extend past
nished wall. Apply plumber tape to threads on
pipe nipple and screw on tub spout.
B-2
B-1
FOR SHOWERHEAD INSTALLATION:
Apply plumber tape to pipe threads on
both ends of the shower arm (1). To
prevent damage to nish on shower arm,
insert wall end of shower arm into shower
ange (2) before screwing arm into riser
connection.
Thread showerhead (3) onto shower arm.
Do not overtighten showerhead.
A.
3
1
2
2
1
1