User Manual

Table Of Contents
DELTANODE FIBER DAS MANUAL
©DeltaNode Solutions 2012
21
Revision 12-03
Below is a list of the most common remote units that are used with the DeltaNode Fiber-DAS system.
Variants are available upon request.
Commonly for all Remote Units is their excellent noise figure, contributing to an overall noise figure for
the whole system from remote to head-end into the base station of < 3 dB for the RF link.
Both chassis comply with IP65 protection for use in any environment. The coating is a durable coating
which aids the convection cooling. No fans are used for the Remote Units. Both chassis are available both
with wall and pole mounting kits as requested.
Comparison table for remote units
Product code
Pout (ETSI)*
Pout (FCC)
Bands
DDR medium power)
26-30
36
1-4
DDS (High power quad band)
30-41
41
1-4
DDH (high power)
32-43
43
1-2
DDH2 (Dual amplifiers)
N/A
46
1
Table 11: Remote comparison table
* Actual power determined by frequency band and spectrum demands.
2.2.1 DDR
Deltanode’s Distributed Radio head is a high performing wideband radio head equipped with a linear
power amplifier supporting all modulations. The light weight, convection cooled IP65 chassis secures the
performance in almost any environment.
ETSI standard
GENERAL SPECIFICATIONS
Noise Figure
Typical
3
dB
Delay excluding optical fiber
< 0,5
µs
Power Supply
Mains
85 264
VAC or VDC
Operating Temperature
-25 - +55
Casing
IP65
OPTICAL SPECIFICATIONS
RF Frequency range
88 2200
MHz
Flatness
+- 3
dB
Optical output power
Nominal
3
mW
DFB Laser output Wavelength
1270 - 1610
nm
Optical return loss
< -40
dB
Optical isolator
min
30
dB
Side-mode suppression ratio
min
30
dB
Maximum optical input power
non destructive
10
mW
SPECIFICATIONS DDR100 (Single Band) & DDR200 (Dual band)
Power Consumption, max
DDR 100
(200)
90 (180) W
Dimensions
WxDxH
300 x 130 x 700
mm
Weight
< 12
Kg