Setup local Network UDP Ports for CGW Access
InorderfortheBird/DeltaNodeCGWtobeabletomakecontactwiththeBGWensurethatthecustomerIT
departmenthasOpenVPNwithUPDports1194to1199.ThisallowsBird/DeltaNodestaticIPaddresstoaccessthe
BGW.
Local Connection to Remote Unit 
Atechniciancandirectlyconnectalaptoptotheremoteunit.Thisisusefulwhenthetechnicianisattheremote
unittroubleshooting.Thedirectconnectionisalsoveryusefulwhenthereisnofiberconnectivitytotheremote
unitandtheinstallerneedstotestand programtheremoteunitduringth
einstallationprocess.
Note:  Bydirectlylogg
ingintheremoteunitandprogrammingthenameoftheremotethereisless
chanceofconfusionwhenalltheremotesareconnectingtotheMasterUnit.
1. Setlaptoptoast
aticIPaddress;somethingalongthelinesof
 IPaddress169.254.48.11
 SubnetMask255.255.0.0
 Gateway169.254.0.1
2. ConnectRJ45Et
hernetcabletothelaptopandtheEthernetportontheremote.
Figure 130   Remote Unit Ethernet Port
Ethernet
Port
3. Useanywebbrowsertoconnecttotheremoteunitstartingwithhttp://169.254.48.1.
Theremoteun
ithasadefaultIPaddressof169.254.48.1to.10.Iftheloginmenudoesnotappeartrythenext
sequentialIPaddress(http://169.254.48.2).ContinuetryingthenextIPaddressuntiltheloginmenuappears.
Figure 131   Remote Unit Login Screen
4. Whentheloginmenuappearstypeinthedefaultcredentials:
 Username:“extended”
 Password:“admin”
5. TheGUImenuswillbethesameaswhenc
onnectingtotheremotethroughtheBGW.