ECG Viewer Manager User Manual
User manual for ECG Viewer Manager Introductions to User Dear Users, Thank you very much for purchasing our Easy ECG Monitor series products. This manual is intended to assist the user in uploading ECG Data from Easy ECG Monitor to PC in a safe and effective manner. Please read this manual carefully before running the system, and follow it to operate. The Manual is published in English and we have the ultimate right to explain the Manual.
User manual for ECG Viewer Manager Information for Operation ¾ Please make sure the well connection of the data cable between PC and Easy ECG Monitor before uploading data, do not pull out the data cable arbitrarily during the data upload. ¾ Data transmission may be interrupted during uploading the data in case of low battery voltage for Easy ECG monitor. ¾ Do not do the key operation on Easy ECG Monitor during the data upload.
User manual for ECG Viewer Manager Table of Contents 1 Overview .......................................................................................................................................... 1 1.1 Features............................................................................................................................................................ 1 1.2 Operating Condition ...............................................................................................................
User manual for ECG Viewer Manager 1 Overview 1.1 Features The waveforms and data saved in Easy ECG Monitor which have been uploaded to PC through ECG data cable can be archived and reviewed by ECG Viewer Manager. It is convenient for user to browse the stored data records, review the ECG waveforms and back up the uploaded data. 1.
User manual for ECG Viewer Manager 2 Installation, Connection and Settings 2.1 Installation of ECG Viewer Manager Insert the CD-ROM which contains the installation software into CD-ROM drive, the software installation will be automatically running or directly running the program "setup.exe" in the root directory of CD-ROM drive, then the window of "ECG Viewer Manager Setup" will be prompted on the screen as shown in Figure 2-1A. Selecting the installation equipment of PC-80 B/Prince 180 B (Wireless, V4.
User manual for ECG Viewer Manager According to the prompts of installation of ECG Viewer Manager to operation, as shown in figure 2-2—figure 2-6; Figure 2-2 Figure 2-3 3
User manual for ECG Viewer Manager Figure 2-4 Figure 2-5 4
User manual for ECG Viewer Manager Figure 2-6 Note: If “Complete” (default) installation is selected,the installed program files will be located in the disk path “C: \Ecg Data Manager” If user doesn’t want to use default installation, please select "Custom" and click "Next" to choose the root directory for locating the program files as shown in Figure 2-3. 2.2 Display Setting for PC 1.
User manual for ECG Viewer Manager 2.3 Device Connection After “ECG Viewer Manager” software is installed, refer to Figure 2-11 to perform cable connection: Figure 2-8 Note: connect the device at first time, the system prompts that “Found New Hardware Your new hardware is installed and ready to use.” on the right side of task bar,as shown in Figure 2-12, it means that USB Driver is installed successfully. Figure 2-9 2.4 Easy ECG Monitor Setting Please power on the Easy ECG Monitor before uploading data.
User manual for ECG Viewer Manager Figure 3-1 Main Menu Screen Description of menu bar: Menu items Menu name pull-down menu Function description Import device data Directly upload the data to PC from the device through provided USB data cable. Import disk data ECG Device User info PC. Wireless data Upload or transmit the data to PC by wireless.
User manual for ECG Viewer Manager Menu operations: Select the functional buttons from the pull-down menu to enter the corresponding operation screen. Description of tool bar: The Tool bar contains shortcuts for menu selection, the user can operate from the menu bar or shortcut keys for quick operation. Click “Exit” to exit the manager system. 3.2 User Archive Management On user archive management screen, the operations: adding new user ID, modifying, finding and deleting archive can be performed.
User manual for ECG Viewer Manager 80 characters. 3.2.2 Modify the User Info After enter the information of the selected user, click the “Ok” button. The user name list is on the left side of window, the detail of User Info and ECG Info is on the right side of window, as shown in figure 3-3, in this screen, you can modify the user information, finally click the “update” buttons. Note:ID and name cannot be modified. Figure 3-3 User info 3.2.
User manual for ECG Viewer Manager Figure 3-5 Found User Screen Description: Field: “ID” and “Name” are optional: you can search user by ID or by name. String: Key word to be searched. Enter the ID and the full name or the first alphabet or character of the name or the first ID number to search the user. If no key word is entered into the “String” field, all the user info will be displayed after clicking “Find”.
User manual for ECG Viewer Manager button, then a window appears on the desktop, as shown in the figure 3-8, figure 3-9, select the record you want to read, click the “ ” button to read the data on PC. After that you can review these data records in the user name list. Figure 3-7 Read Figure 3-8 Read Note: The scanning time of ECG information will be different depending on the data size and computer speed; it would last for 6 minutes at most if the device contains large amounts of data.
User manual for ECG Viewer Manager Method 2: After the device is connected to PC via USB data cable, the operating system of PC will add a removable disk named “EASY ECG” after it performs automatic scanning as shown in Figure 3-10. Double click this disk name, you will find there four file folders and one text file: ECG0, ECG1, ECG2, ECG3 and README.TXT” which can be copied to PC directly.
User manual for ECG Viewer Manager 3.3.2 Import Device Data Ensure correct connection between the device and PC via USB data cable, select the ECG records you want to upload from the user name list, click the submenu “Import device data” in the pull-down menu of the “ECG device” or click the Tool bar icon “ ”, then a window appears on the desktop, as shown in the figure 3-8, figure ” button to load the data into PC.
User manual for ECG Viewer Manager 3.3.3.2 Non-real-time wireless uploading When the ECG monitor is under “Review” → “Measurement result” status, press the “■ OK” button, the device ” or “ will display “Sending…….” Click the icon “ ” on PC side, the non-real-time wireless reception screen appears on the interface with a display of “user (sb) is receiving the wireless data” as shown in Figure 3-14. The appearance of Figure 3-15 means the data record has been received and saved in PC successfully.
User manual for ECG Viewer Manager Figure 3-16 3.4 Review ECG Waveform Records, All ECG Waveforms, Statistical Result and Irregular Rhythm Event Plot Select the ECG record you want to review in user name list on the left of main menu, and then you can not only review this record in detail, but also enter some remarks and store them. On the left of main menu is user name list and the detail of ECG record information.
User manual for ECG Viewer Manager 3.4.1 Review ECG Waveform Records Click the icon “ ” to view the ECG waveform as shown in Figure 3-17 Waveform area The new movable window The upside-down The triangle triangle Waveform zooming area Figure 3-17 the ECG Waveform Screen According to different measurement modes, there are two display modes for ECG waveform record: Quick measurement by built-in electrodes and continuous measurement by lead wire.
User manual for ECG Viewer Manager this event. If you want to re-mark the cancelled irregular rhythm event, click the “Cancel” button, then a dialog box pops up on the screen and reminds you that “Are you sure to restore this irregular rhythm mark?”, finally, click the “OK” button to remark this event. After that the normal triangle will disappear, and this irregular rhythm event will be taken into account in the statistical result and irregular rhythm event plot again.
User manual for ECG Viewer Manager 3.4.3 Statistical Result The statistical result is for ECG records which are uploaded by the method of non-real-time wireless reception and measured by mode of continuous measurement. Click the icon “ ” to get the statistical result for this ECG record as shown in Figure 3-19.
User manual for ECG Viewer Manager Figure 2-20 Irregular Rhythm Trend Graph Screen 3.5 Delete and Print ECG Waveform Records 3.5.1 Delete the ECG Waveform Records Select the corresponding record, click the submenu “Delete” in the pull-down menu of the “ECG record” or click the Tool bar icon “ ”, then a window appears on the desktop, as shown in the Figure 3-21. Please follow the prompts to operate. Figure 3-21 Delete the Records 3.5.
User manual for ECG Viewer Manager “ ”: Full screen displays the records. “ ”: Print the current report displayed. If the content of records is more than one page, click this button to set the start, end page and the printing copies according to your need. “ “ ”: Save. Click this button can save the ECG records in picture format on PC. ”: If the content of records is more than one page, click this button to turn the page up and down so as to preview all records. “ ”: Close. Close the current preview.
User manual for ECG Viewer Manager Figure 3-23 Print Preview (ECG Statistical Result) Figure 3-24 Print Preview (Irregular Rhythm Event Plot) 21
User manual for ECG Viewer Manager Figure 3-25 Print Preview (All ECG Waveforms) 3.6 About Click the submenu “About” in the pull-down menu of the “Help”, or t or click the Tool bar icon “ ”, and then the dialog box about the system appears, as shown in the figure 3-26.
User manual for ECG Viewer Manager 3.7 Exit the System Click the submenu “Exit” in the pull-down menu of the “ECG device”, or click the Tool bar icon “ ”, and then the dialog box about the system appears, as shown in the figure 3-27. Figure 3-27 Exit the System 3.8 Troubleshooting No. Misinformation 1 Failing to search the device! 2 No searched ECG information! 3 4 5 (for wireless reception) No searched the ECG device! No found printer in the system, Possible Reason Solution 1.