Owner`s manual

ALARM SIGNAL & LED INDICATION
Note : ■■■ represents “beep, beep, beep”
Detector
Operation
Green Red Yellow
Alarmsignal
Power indication Alarm signal Fault signal
Normal Operation
Flash once per
minute ¤
- - -
Alarm Condition - 4 beeps + ash ¤ -
■■■■ -1s -■■■■
-1s -■■■■ …
Silence (hush) mode
under
alarm condition
- 4 ashes ¤ - -
Interlink signal
input (slave)
- beep + ash ¤ - ■■■■■■■……….
To activate
silence(hush) unit
under interlink
signal input
- Flash ¤ - -
Pre-alarm warning
CO level (40 ppm
or greater level
detected)
-
Flash once every
8 seconds until
alarm ¤
- -
Memory function-
indicates the alarm
has been activated
before(not from
test button) due to
whatever reason
- - -
■--8s--■--8s--■
1 beep every 8
seconds last for 12
hours. Press button
once to reset to
normal mode
Low Battery
Warning
- -
1 beep + ash
every minute ¤
■-1 min-■-
1min-■…….
Sensor Fault - -
2 beeps +
ash every 8
seconds ¤
■■-8s-■■-8s-■■-
8s-…………
End of sensor
lifetime warning
- -
3 Beeps +
ash every
minute ¤
■■■-1min-■■■-
1min-■■■……
Temporary delay
warning signal –
(Push button to
temporarily disable
low battery- or end
of life- warnings for
12 hours)
-
Flashes 3 times
after a push of the
button
¤
(Push button
again to return to
warning mode at
any time)
- -