User's Manual
6
Default settings indicated by parenthesis.
“Time out” saves power by turning off the display after selected amount of time .
Feed is an internal timer to remind you to jam.
Jam lock inhibits free run code with out jamming.
Flash increases or decreases the brightness of the held frames.
Hold displays the clapped frame 2 seconds after the display goes out.
EL backlight lamp can be disabled in low brightness.
Low brightness selects lower light levels (1 = highest).
To display scrollback of the previous claps push the button while sticks are closed.
The memory is cleared at power off.
EXAMPLE: Enable the display timeout and set the timeout value to 120 sec.
Enable tout
1] Turn TS-3 power off.
2] Turn rotary switch to Position 7
3] Turn TS-3 power on. The display will read “node A”
4] Turn rotary switch to position 1. The display will read “tout OFF” (if disabled) or “tout ON”
(if enabled).
5] To enable the timeout mode turn toggle switch to On (run). Press the push button to
confirm change. The display will read “tout ON”.
6] To exit mode A turn rotary switch to position 0. Display will read “return”. Turn toggle
switch to on (run) and press the push button. The TS-3 will reset and time code will roll.
Set tout to 120 sec.
1] Turn TS-3 power off.
2] Turn rotary switch to Position 6.
3] Turn slate power on. The display will read “node B”.
4] Turn rotary switch to Position 1. The display will read “tout xx” (xx = previous setting).
5] To change the timeout value set the toggle switch to on (run). Press the push button to
change the timeout value.
6] To exit mode B turn rotary switch to position 0. The display will read “return”. Set the
toggle switch to on (run) and press the push button. The TS-3 will reset and time code will
roll.