Protocol Specs
06.April.06
18/28
EVENT PARAMETER
function example
MU ON OUTPUT MUTE ON/OFF change MUON<CR>
OFF MUOFF<CR>
ZM ON MAIN-ZONE ON/OFF change ZMON<CR>
OFF ZMOFF<CR>
Z2 PHONO MULTI ZONE-2 source change Z2PHONO<CR>
| ---The name of PARAMETER is |
AUXIPOD the same as that of the time of SI COMMAND. Z2AUXIPOD<CR>
SOURCE MULTI ZONE-2 mode cancel Z2SOURCE<CR>
** MULTI ZONE-2 VOLUME change , **:10 to 99 by ASCII Z280<CR>
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
99 = ---(MIN)
ON MULTI ZONE-2 ON/OFF change Z2ON<CR>
OFF Z2OFF<CR>
Z2MU ON ZONE2 OUTPUT MUTE ON/OFF change Z2MUON<CR>
OFF Z2MUOFF<CR>
Z3 PHONO MULTI ZONE-3 source change Z3PHONO<CR>
| ---The name of PARAMETER is |
AUXIPOD the same as that of the time of SI COMMAND. Z3AUXIPOD<CR>
SOURCE MULTI ZONE-3 mode cancel Z3SOURCE<CR>
** MULTI ZONE-3 VOLUME change , **:10 to 99 by ASCII Z380<CR>
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
99 = ---(MIN)
ON MULTI ZONE-3 ON/OFF change Z3ON<CR>
OFF Z3OFF<CR>
Z3MU ON ZONE3 OUTPUT MUTE ON/OFF change Z3MUON<CR>
OFF Z3MUOFF<CR>
The PARAMETER of Z2, Z3 EVENT : Uses two ASCII characters. (see page4 J) section)