function example
PS BAS UP BASS UP/DOWN , direct change to **dB PSBAS UP<CR>
BAS DOWN **:00 to 99 by ASCII , 50=0dB PSBAS DOWN<CR>
BAS ** ---AVR-X2000/E400 can be operated from -6 to +6(44 to 56)
PSBAS 50<CR>
BAS ? Return PSBAS Status PSBAS ?<CR>
TRE UP TREBLE UP/DOWN , direct change to **dB PSTRE UP<CR>
TRE DOWN **:00 to 99 by ASCII , 50=0dB PSTRE DOWN<CR>
TRE ** ---AVR-X2000/E400 can be operated from -6 to +6(44 to 56)
PSTRE 50<CR>
TRE ? Return PSTRE Status PSTRE ?<CR>
DRC AUTO Dynamic Compression direct change PSDRC AUTO<CR>
DRC LOW PSDRC LOW<CR>
DRC MID PSDRC MID<CR>
DRC HI PSDRC HI<CR>
DRC OFF PSDRC OFF<CR>
DRC ? PSDRC ?<CR>
LFE UP LFE UP/DOWN , direct change to **dB PSLEE UP<CR>
LFE DOWN **:00 to 99 by ASCII , 00=0dB, 10=-10dB PSLFE DOWN<CR>
LFE ** ---AVR-X2000/E400 can be operated from 0 to -10 PSLFE 10<CR>
LFE ? Return PSLFE Status PSLFE ? <CR>
EFF UP EFFECT UP/DOWN , EFFECT LEVEL direct change to **dB PSEFF UP<CR>
EFF DOWN **:00 to 99 by ASCII , 00=0dB, 10=10dB PSEFF DOWN<CR>
EFF ** ---AVR-X2000/E400 can be operated from 1 to 15 PSEFF 10<CR>
EFF ? Return PSEFF Status PSEFF ?<CR>
DEL UP DELAY UP/DOWN , direct change to ***dB PSDEL UP<CR>
DEL DOWN ***:000 to 999 by ASCII , 000=0ms, 300=300ms PSDEL DOWN<CR>
DEL *** ---AVR-X2000/E400 can be operated from 0 to 300 PSDEL ***<CR>
DEL ? Return PSDEL Status PSDEL ?<CR>
PS COMMAND : "*" parameter uses two or three ASCII characters. (see page6 J) section)